Calibrating the Magnets and Fixing Them in Place
7
Fix the magnets in place.
Be careful not to move the magnets from their adjusted positions when you fix them in place.
Patch type
Keep the magnet attached to the masking tape as you lift up the tape. When you do this, leave one side of the tape
attached, so the magnets remain in their adjusted positions.
Remove the non-adhesive backing paper from the back of the magnet, and then re-stick the masking tape back the way
it was. Press on the magnet, through the masking tape, to fix it in place, then remove the masking tape.
Arm type
Use needle nose pliers to tighten the cable ties to fix the magnets in place, then use snips to cut off the excess parts of
the cable ties.
8
Rotate the bicycle's crank set slowly at about 30 rpm, in the forward direction, and confirm that the LED
lights green for each rotation.
Confirm that the left and right LEDs light green for at least seven rotations.
If the LED lights red, then you are turning the crank set too fast. Turn it slowly at about 30 rpm, in the forward direction.
9
Press and hold down the switch on the right transmitter for at least 5 seconds.
The LEDs light green for 10 seconds. The calibration data is saved and the sensor exits the magnet calibration mode.
In step 8, if you rotate the crank fewer than 6 rotations or if there are vibrations while calibrating the magnet, the LED lights red for 10
seconds and the sensor exits the magnet calibration mode. You must re-calibrate the magnets.
To exit the magnet calibration mode while calibrating, briefly press the switch during the calibration. The left and right transmitters' LEDs
flash orange 5 times, the calibration data is not updated and the sensor exits the magnet calibration mode.
In addition, if calibration is not completed within 30 minutes after switching to the magnet calibration mode, the calibration data is not
updated and the sensor exits the magnet calibration mode.