Sensor Connection

Symptom
The pedaling monitor
sensor cannot pair to the
Cyclocomputer.
Cause
The sensor is in sleep state.
There are no batteries in the
sensors.
Or, the positive and negative
terminals of the batteries are
reversed.
The sensors' batteries are
dead.
The sensor's operating mode
is not correct.
The device numbers are not
set correctly.
There is a different 2.4 GHz
wireless device or a microwave
nearby.
The sensor and Cyclocomputer
are too far apart.
The Cyclocomputer does not
operate normally.
The magnet is not installed
correctly.
The magnetic field of the
magnet is weakening.
The magnetic field detector is
broken.
The junction cable of the right
sensor has been cut.
The circuit board in the
transmitter is broken.
User
Activate the transmitter by rotating the bicycle's crank set at least three times.
The sensor automatically enters a sleep state if it is still for five minutes.
Confirm that the batteries (CR2032, 3V) are correctly installed in the left and
right pedaling monitor sensors. Insert the batteries with the + mark visible.
Press on the right transmitter until you hear a click. After loading a battery into
the left transmitter, rotate the battery cover to its proper position. After loading
batteries, check to confirm that the LED is lit green.
Replace the batteries. If the LED does not light for more than five seconds after
batteries are loaded, remove the batteries, wait for at least one minute, and
then re-load them. If the LED still remains unlit, it means that battery power is
low. Replace the batteries with new ones.
Use Cyclocomputer sensor information to check the batteries. If the battery
level is 2.5 V or less under normal temperature, replace the batteries.
Battery voltage is reduced by low temperatures, which may result in unstable
operation.
Check the operating modes of the left and right pedaling monitor sensors.
Check the device numbers of the left and right sensors, and then pair them
again.
Pairing may fail or require a long time because of the interference from
microwave ovens or other wireless devices. Move away from any other wireless
devices and move the sensor closer to the Cyclocomputer.
The attempt to pair to the sensor times out after 30 seconds. If they do not pair
after 30 seconds, move to a location where there is no electronic interference
and try to pair again.
The sensors have a wireless range of about 10 meters, but this could be limited
by the existing radio wave environment. Move the sensor as close as possible
to the Cyclocomputer.
Check the Cyclocomputer's charge and operations.
Confirm if a different ANT+ sensor can be paired.
Contact your dealer.
Contact your dealer.
Contact your dealer.
Contact your dealer.
Troubleshooting
Solution
Dealer
Replace the batteries and check the
connection.
Wait for at least five minutes until the
sensor enters the sleep state. Next,
rotate the crank at least three times
and check the connection again.
If a magnet is detected but does not
result in activation, check to make sure
that the magnet is installed correctly.
An incorrectly installed magnet may
result in improper operation.
Check the distance between magnets
and the sensor.
Magnetism may have gotten weaker
due to age-related deterioration.
If operation is possible only when
the distance between magnets and
the sensor is closer than what is
prescribed, replace the magnets with
new ones.
Please visit our website for more
information.
See "Calibrating the Magnets and
Fixing Them in Place" (page 15) of the
Installation Manual (for dealers).
If the sensor's LED does not light,
please visit our website.
See "Checking Operation of the
Sensors" (page 7) of the Installation
Manual (for dealers) .
If the sensor's LED does not light,
please visit our website.