Symptom
The torque chart is not near 0
N after calibrating zero point in
power meter mode.
The torque value does not
appear correctly if there are
loads on the cranks or pedals
when paired to a different
company's cyclocomputer while
in the power meter mode.
Display
Symptom
The power value is not correct.
The left and right sides of
the vector chart or efficiency
display are obviously different.
The proportions of the left
and right power values are
obviously different.
When pedaling with only one
leg, the side not being pedaled
is extremely far from 0 W.
The power value and/or vector
are not displayed occasionally.
The vector chart is rotating.
Cause
There are loads on the cranks or
pedals.
The crank length is not set
correctly.
The calibration may not have
been done correctly.
Cause
The zero point is incorrect.
Temperature (air temperature)
learning is not performed.
There is a problem with the
temperature (air temperature)
learning result.
The calibration under load may
not have been done correctly.
This is a problem with either
the left or right sensor.
The sensors' batteries are
dead.
A magnet other than the
provided magnets is attached
to the frame.
The magnet calibration may
not have been done correctly.
User
Position either the left or right crank at 6 o'clock before calibrating from the
Cyclocomputer. For more information about calibration, refer to the other brand of
Cyclocomputer's user documentation.
Remove any load from the left and right cranks and pedals, and then calibrate the
zero point. The zero point may be incorrect if a load is applied.
The zero point may be incorrect if there is a load on either the left or right cranks or
pedals. Because the left and right zero point is calibrated at the same time for the
power meter mode.
The value that is displayed following calibration with another brand of
Cyclocomputer is the total of the left/right calibration values. Values may vary
somewhat due to temperature and the crank angle, but this is normal.
Contact your dealer.
Contact your dealer.
User
Installing the cranks and pedals can cause a slight change in the zero point.
Be sure to calibrate the zero point after installing cranks and pedals.
When using the pedaling monitor mode, calibrate the zero point for both the left
and right sensors.
Calibrate the zero point with pedals installed.
If there has been a change in temperature of 4°C or more since the last zero
point calibration, calibrate the zero point again. Also, accurate measurement
will not be possible if calibration is performed before the sensor is acclimated to
external air temperature. It takes at least 20 minutes for the sensor to become
acclimated to the current outside temperature.
This device uses a temperature (air temperature) learning function to
automatically calibrate its zero point as the temperature changes. This
function maintains accuracy as the temperature changes during a ride. As the
temperature varies, it is necessary to calibrate the zero point more than twice,
so the most recent six times are used for calibrating using this function. The
results of the zero point calibration are recorded if the temperature varies more
than 4°C from the zero point calibration recorded previously.
Check if a change in temperature has caused a change in the zero point.
After the crank has become sufficiently acclimated to the external temperature,
check the Force Preview. Next, move to a location where the external
temperature is different, wait for 20 minutes, and then check the Force Preview
again.
If there is a major difference between the zero points, it could mean there is a
problem with the learning function. If this happens, use the ZeroCal application
to initialize the sensor whose zero point is off. Learning function results are
stored in a log file, and can be checked using the Cyclo-Sphere screen and the
device information window.
Contact your dealer.
Contact your dealer.
Replace the batteries. If the LED does not light for more than five seconds after
batteries are loaded, remove the batteries, wait for at least one minute, and
then re-load them. If the LED still remains unlit, it means that battery power is
low. Replace the batteries with new ones.
Use Cyclocomputer sensor information to check the batteries. If the battery
level is 2.5 V or less under normal temperature, replace the batteries.
Battery voltage is reduced by low temperatures, which may result in unstable
operation. Frequent replacement of batteries is recommended during winter.
Contact your dealer.
Contact your dealer.
Troubleshooting
Solution
Dealer
Please visit our website.
Please visit our website.
Solution
Dealer
Please visit our website.
Please visit our website.
Check if there is a magnet other than
the provided magnets attached to the
frame. This product will not operate
properly if there are magnets installed
for another brand of power meter, etc.
Check if the magnets are installed
correctly. Correctly calibrate magnets.