Messkreis
Messspannung
............................................................................................................................................. ±45 V
m
Messstrom
bei
......................................................................................................................................... ≤ 400 μA
m
F
Innenwiderstand DC
i
Umwelt/EMV
EMV ......................................................................................................................................................... IEC 61326-2-4
Umgebungstemperaturen:
Betrieb ..................................................................................................................................................... -40...+70 °C
Transport ................................................................................................................................................. -40...+85 °C
Lagerung ................................................................................................................................................. -40...+70 °C
Klimaklassen nach IEC 60721:
Ortsfester Einsatz (IEC 60721-3-3) .....................................................................3K7 (ohne Betauung und Eisbildung)
Transport (IEC 60721-3-2) ............................................................................... ..2K4 (ohne Betauung und Eisbildung)
Langzeitlagerung (IEC 60721-3-1) .................................................................... 1K5 (ohne Betauung und Eisbildung)
Mechanische Beanspruchung nach IEC 60721:
Ortsfester Einsatz (IEC 60721-3-3) ........................................................................................................................ 3M4
Transport (IEC 60721-3-2) ..................................................................................................................................... 2M4
Langzeitlagerung (IEC 60721-3-1) ........................................................................................................................ 1M12
Anschluss
Anschlussart.......................................................................................................................Schraub- oder Federklemme
Schraubklemmen:
Nennstrom ............................................................................................................................................................≤ 10 A
Anzugsmoment ..................................................................................................................0,5...0,6 Nm (5...7 lb-in)
Leitergrößen..................................................................................................................................................AWG 24-12
Abisolierlänge ....................................................................................................................................................... 8 mm
Starr/flexibel............................................................................................................................................0,2...2,5 mm
Flexibel mit Aderendhülse mit/ohne Kunststoffhülse.........................................................................0,25...2,5 mm
Mehrleiter starr........................................................................................................................................0,2...1,5 mm
Mehrleiter flexibel...................................................................................................................................0,2...1,5 mm
Mehrleiter flexibel mit Aderendhülse ohne Kunststoffhülse...............................................................0,25...1,5 mm
Mehrleiter flexibel mit TWIN Aderendhülse mit Kunststoffhülse .......................................................0,25...1,5 mm
64
................................................................................................................................... ≥ 120 kΩ
isoEV425_D00126_09_M_XXDE/03.2019
Technische Daten
2
2
2
2
2
2