SPARE PARTS
Original spare parts have been specially designed for
our equipment. The use of non-original spare parts
may cause variations in performance or reduce the
foreseen level of safety. We decline all responsibility
for the use of non-original spare parts.
Ordering spare parts
For easy ordering of spare parts includes the follow-
ing:
The order number of the part.
The name of the part.
The type of the machine or welding torch.
Supply voltage and frequency from the rating
plate.
Serial number of the machine.
EXAMPLE: 2 pcs., code 30451 fan SUNON for machi-
ne 160, 1x230V 50/60Hz, serial number ...
Procedure of checking process of
inverter welding machine
To carry out the checking it is necessary to use sui-
table measuring instrument for measuring checks,
for example REVEX 51 (2051). Machine MEGMET
must not be used, in other case there is a risk of des-
tructtion of the machine.
1.
Switch on the main switch on the machine.
2.
Plug supply terminating unit into the measuring
instrument.
3.
Set the measuring instrument according to the
guidelines for measuring of contact resistance.
4.
By the help of a probe measure contact resistan-
ce on parts connected to the ground, for examp-
le cover screw. Contact resistance must be lo-
wer than 0.1 Ohm.
5.
Set the measuring instrument according to the
guidelines for measuring method Leaking cur-
rent.
6.
Measure leaking current and repeat measuring
with opposite polarity.
7.
Set the measuring instrument according to the
guidelines for measuring method substitute
leaking current.
8.
Measure substitute leaking current and repeat
measurement with opposite polarity
9.
Set the measuring instrument according to the
guidelines for measuring method Current
through leading wire.
10. Measure current in protective leading wire and
repeat measuring with opposite polarity.
11. In none of measurements according to points 5 -
10 current value must not be higher than 3.5
mA.
The welding machine must go through regular
checking according to EN 331500/1990.