picture 1 – CONTROL PANEL
Signalling, control and telephone cables
Radio and television transmitters and receivers
Computers and control and measurement ins-
truments
Security and protection instruments
Persons fitted with pace-makers, hearing aids and
similar equipment must consult their doctor before
going near a machine in operation. The equipment's
installation environment must comply to the protect-
tion level of the frame i.e. IP 23 S. The system is
cooled by means of the forced circulation of air, and
must therefore be placed in such a way that the air
may be easily sucked in and expelled through the
apertures made in the frame.

Connection to the electrical supply

Before connecting the welder to the electrical sup-
ply, check that the machines plate rating corres-
pondds to the supply voltage and frequency and that
the line switch of the welder is in the „0" position.
Connection to the power supply must be carried out
using the four polar cable supplied with the system,
of which:
2 conducting wires are needed for connecting
the machine to the supply
the fourth, which is YELLOW GREEN in colour is
used for making the „EARTH" connection
Connect a suitable load of normalised plug (2p+e) to
the power cable and provide for an electrical socket
complete with fuses or an automatic switch. The
earth terminal must be connected to the earth
conducting wire (YELLOW-GREEN) of the supply.
NOTE: Any extensions to the power cable must be of
a suitable diameter, and absolutely not of a smaller
diameter than the special cable supplied with the
machine.
WARNING: While using the machine 190 on higher
welding current, the power take off may exceeds 16
A. In this case it is necessary to change the default
supply plug for industrial plug with 20 A protection.
At the same time this protection must be in
accordance with implementation and protection in
the distribution of electricity.
Other methods of connection are fixed connection to
separate circuit (such circuit must be protected by
circuit-breaker or fuse max. 25 A), or connection to
three-phase network 3x400/230V TN-C-S (TN-S).
In case of connection to three-phase network, the 5-
pin plug 32 A must be used. Phase conductor - black
(brown) connect in the plug to one of clamp marked
L1, L2 or L3. Null conductor - blue - connect to clamp
marked (N), white/green conductor connect to clamp
marked (Pe). This way modified supply cable of the
machine can be pluged to the three-phase socket
outlet, which must be protected by circuit-breaker or
fuse max. 25 A.
WARNING: Machine may not be connected to inter-
linked voltage (i.e. voltage between two phases). In
this case the machine may be demaged.
-34 -