Herunterladen Inhalt Inhalt Diese Seite drucken

Control Aparatus; Connection Of The Welding Cables; Setting Of The Welding Parameters - Fenix 200 Bedienungsanweisung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 44
Picture 2
Such modifications could be made only by com-
petent person with electrotechnical qualification.
Control apparatus
PICTURE 1
Position 1 Position 1 LED diode signal a chosen
welding methode - MMA.
Position 2 LED signal a chosen welding methode -
TIG.
Position 3 Display shows the set value.
Position 4 LED signalize a set value for keeping
function of HOT START (only for MMA
methode) – the duration of function
HOT-START is possible to set in rangge of
0-2 seconds.
Position 5 LED signalised setting values welding
current pulse frequency (for TIG method)
can be set from 0 to 500 Hz.
Position 6 MET button to select the method of
MMA (stick electrode) or TIG.
Position 7 LED signalised setting values welding
current run - for TIG, in MMA method
this
diode
features VRD.
Position 8 LED signalising of activation ARC-FORCE
(only for MMA method) or setting the
value ending welding current (for TIG).
Position 9 SET button for selecting of each function
(check of the set value or its change)
Position 10 LED indicating the setting values of
welding current (common for MMA and
TIG).
Position 11 LED indicating the setting values of
welding current (common for MMA and
TIG). LED signalising setting values for
HOT-START (only for MMA method) - the
percentage increasing in the welding
current at the beginning of the welding
process. Function% HOT-START can be
signalizing
the
security
adjusted between 0 (function disabled)
to increase the maximum starting current
of 100%. (Maximum of 150 A or 190 A
depending on the type of machine).
PICTURE 2
Position 1 Main switch. In position „0" the welding
machine is OFF.
Position 2 Power cord.
Position 3 Quick minus pole.
Position 4 Quick plus pole.
Position 5 Remote connector.
Position 6 Encoder control.
Position 7 Digital panel.

Connection of the welding cables

With the machine disconnected from the supply,
connect the welding cables, welding torch and earth-
cable. The polarity must be choosen according to
welding method. For MMA method the polarity
determines the producer of electrodes according to
their type. The welding cables should be as short as
possible, close to each other, and positioned at floor
or close to it.
WELDING PART
The material which should be welded, must always
be connected to the ground for reducing of
electromagnetic radiation. Special attention must
also be given to grounding of the welding material to
not increase the risk of injury or damage to other
electrical equipment.

Setting of the welding parameters

START THE MACHINE (RESTART FROM THE MMA
METHOD)
After turning the machine is first shown on the
display for about 2 seconds statues of security
functions V.R.D. (On/OFF). After that is displayed for
-35 -

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

160

Inhaltsverzeichnis