Herunterladen Inhalt Inhalt Diese Seite drucken

Fenix 200 Bedienungsanweisung Seite 36

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 44
another 2 seconds setting of the function ARC-Force:
AF0 - function is off, AF1 - additional energy for
shortening the arc 50%, AF2 - additional energy for
shortening the arc 100%. During this condition is
possible between different settings to choose ARC-
FORCE rotary encoder. Then is shown the set current
welding size and signaling method MMA.
STARTING THE MACHINE (RESTART FROM THE TIG
METHOD)
After the switching the machine on it is shown the
set size of welding current and signaling the TIG
method.
SETTING OF THE WELDING METHOD
After turning the machine back to the last selected
welding method before shutting down. Press the
button MET (position 6, Picture 1), you can choose
the second method of welding.
SETTING OF WELDING PARAMETERS FOR INDIVI-
DUAL METHODS
POSSIBILITY OF ADJUSTMENT PARAMETERS FOR
MMA METHOD:
Welding current 10 - 150 A (series 160), 10 –
190 A (series 200)
Increase the value of starting current HOT-
START 0 - 100 % welding current, max. 150 A
(series 160), 190 A (series 200).
Reduction the value of starting current SOFT-
START 0 to -90 % welding current with
continuous increase.
Starting time of the activity current 0 to 2,0 s.
MMA method – setting of the welding current
Po After the setting any parameter after a period of
inactivity machine always returns to the default state
when Iw LED lights up and the display shows the size
of the welding current. Rotary encoder (position 6,
picture 2) can directly set required value of welding
current.
Method MMA - setting of value HOTSTART
Press button SET (position 9, picture 1) until LED %
(position 11, picture 1) is on as in the picture. Set up
required value of current increase in % with
a potentiometer (position 6, picture 2). If there is
value 30 on the display it means increase of start
current by 30 %.
MMA method – setting of the time value of HOT-
START
Press the SET button (position 9, picture 1), to light
up with (position 4, picture 1) as shown on the
picture. Rotary encoder (position 6, picture 2) set the
required value duration HOT-START.
EXAMPLE:
1.
When the set welding 100 A (lights LED Iw,
position 10 picture 1, and LED MMA (position 1,
picture 1), display shows 100 (100 A).
2.
By pressing the SET button LED % light up
(position 11, picture 1). It is possible to set the
value of the starting current - HOT-START for
example abou 50 % higher (set on the display by
potenciometer 50). Final „starting current" is
150 A. Function HOT-START is possible to turn of
by setting on 0 %.
3.
Again by pressing the SET button with LED
(position 4, picture 1). It is possible to set the
value of an encoder activation period starting
current - eg 0.2 s.
4.
When starting the arc welding ignition by
current 150 A for 0,2 s then the current drops to
the set value lw 100 A.
-36 -

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

160

Inhaltsverzeichnis