Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning - Maintenance - Repairs; Disposal; Technical Data; Sources Of Error - Heraeus Palajet Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Operating instruction – method and instructions for use
8
Cleaning – Maintenance – Repairs
Clean the surface of the apparatus with a moist cloth. Make sure that no water can enter.
Do not use aggressive cleaning agents. Check the water separator weekly and remove accumulated water as required.
Check the compressed-air supply and the compressor if leaks occur.
WARNING
The apparatus may be damaged by moisture!
Inspection of the pneumatic components is recommended every two years (see paragraph 12 Service).
WARNING
Use only approved original spare parts and accessories.
The use of parts from other sources involves unknown risks and is not permitted under any circumstances.
WARNING
The function and safety of the apparatus can only be guaranteed if all required tests, services and repairs are
conducted by Heraeus service contractors or by technicians trained by the manufacturer.
Heraeus Kulzer GmbH will not accept liability for damages resulting from damage to the apparatus resulting from incorrect
repair work that was not conducted by Heraeus service contractors or by technicians trained by the manufacturer, or if original
spare parts or accessories were not used to replace parts or accessories.
8.1

Disposal

The apparatus is designed for a service life of 10 years.
For the disposal of spare parts, or the unit, please contact the Heraeus Kulzer subsidiary directly in your country.
9

Technical data

Compressed air connection
Nominal pressure
Plunger speed
Compression force on the fill cylinder
Height
Width
Depth
Weight
10

Sources of error

Error sources
Incorrect operating Pressure
Too fast or too slow injection
speed
11

Name plate

Injection process for manufacturing dentures
5 – 10 bar
4 bar
0 – 50 mm / sec
approx. 2 KN
approx. 400 mm
approx. 290 mm
approx. 265 mm
approx. 13.5 kg
Remedy
– Pull setting knob on the regulator­ / filter unit upwards until raster snaps out
– Adjust regulation of operating pressure to 4 bar and press setting knob downwards until it snaps in
– Remove protective stirrup above the throttling check valve
– Remove locknut on the throttling check valve
– Adjust knurled head screw according to the desired speed and fasten the locknut
– Replace protective stirrup
– Hoisting speed = upper throttling check valve
– Sink speed = lower throttling check valve
2013-04-0800
Heraeus Kulzer GmbH
Grüner Weg 11, 63450 Hanau
P = 5-10 bar
P
= 4 bar
N
66020450
Palajet
®
GB
- 7 -

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis