Pointek CLS 200 (standard probe length): top or side mounting
vertical
normal process
level
High level alarm
• normally mounted into the vessel top, or
• through the tank wall at the detection
level
Pointek CLS 200 standard configuration with extensions: top mounting
• Designed for top mounting, for high or low level alarm. Suspend the probe vertically so
that it reaches into the process at the desired detection level.
Process Cautions
• The maximum allowable torque on a horizontally installed rod is 15 Nm.
• Keep unit out of path of falling material, or protect probe from falling material.
• Avoid areas where material build up occurs.
• Take into account material surface configuration when installing unit.
• Ensure tensile load does not exceed probe or vessel ratings.

Mounting Instructions

Pointek CLS 200 is available in two thread types: NPT, or BSP
connection threads are of the same type, then simply screw Pointek CLS 200 into the process
connection, and hand tighten.

Maintenance

Pointek CLS 200 requires no maintenance or cleaning.
Unit Repair and Excluded Liability
For detailed information, please see the inside back cover.
1.
A
sanitary connection, type 3A, is also available.
Page EN-4
Pointek CLS 200 (analog/digital) – QUICK START MANUAL
horizontal
Low level alarm
• mounted through the tank wall at the
detection level
1
. Make sure the mounting
normal process
level
50 mm
(2") min
7ML19985QE81