Herunterladen Inhalt Inhalt Diese Seite drucken

Connection 230 V; Function Check; Warning Information - Truma Combi 4 Einbauanweisung

Vorschau ausblenden Andere Handbücher für Combi 4:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3

Connection 230 V

(Combi 4 E / Combi 6 E)
he 230 V electrical connection must always be made by
an expert (in accordance with VDE 0100, part 721 or
IEC 60364-7-721, for example, in Germany). The information
given here is not intended as instructions for you to carry out.
It is for assisting the expert assigned to carry out the job, act-
ing as auxiliary information when connecting the appliance!
Always make sure to con nect carefully, observing the correct
colours!
For maintenance and repair work a disconnecting device must
be provided on the vehicle for all- pole disconnection from the
power supply, with at least 3.5 mm contact clearance.
Connect to the mains supply
via the 150 cm long silicone
cable by means of a fuse-
protected line of at least 10 A
(better 16 A).
All cables must be secured
with cable clips.

Function check

After installation, the gas feed line must be tested for tight-
ness by the pressure-drop method. A test certificate must be
issued (e.g. in accordance with DVGW Work Sheet G 607 in
Germany).
Then check all functions of the appliance, as specified in the
operating instructions, in particular the water content draining
function. There shall be no guarantee claims for damage
caused by frost!
The operating instructions must be handed to the owner of
the vehicle.

Warning information

The installer or vehicle owner must apply the yel low sticker
with the war ning information, which is enclosed with the
applian ce, to a place in the vehicle where it is clearly visible to
all users (e.g. on the wardrobe door)! Ask Truma to send you
stickers, if neces sary.
18

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Combi 4 eCombi 6Combi 6 e

Inhaltsverzeichnis