Herunterladen Inhalt Inhalt Diese Seite drucken

Installing Bench Sensor F2 (Optional) - Harvia SENTIO just sauna combi weiß Gebrauchs- Und Montageanleitung

Saunasteuerung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Installation instructions, only for experts
5. Place the two half-shells together, screw them together using the two cross-
head screws 3 (9 mm) and check whether the heater sensor has been
securely closed.
6. Install the heater sensor on the rear of the heater using the two wood screws
enclosed 6 (16 mm).
Fig. 4 Installing the heater sensor (F1)

4.4. Installing bench sensor F2 (optional)

The bench sensor must be installed on the wall of the sauna room, above the
rear bench seat. A distance of approx. 15 cm to the roof of the sauna cabin must
be maintained.
To install the bench sensor, perform the following steps:
1. Lay the two 2-pin bench sensor wires in the wall of the sauna room, leading
them to the bench sensor installation location and affix the bench sensor
wires using wire clips.
Heater sensor half-shells
1
Connection panel
2
Cross-head screws (9 mm)
3
Heater sensor
4
Heater sensor wires
5
Wood screws (16 mm)
6
p. 16/46

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Sentio just sauna combi schwarz

Inhaltsverzeichnis