Instructions for use for the user
The preset humidity can be set to between
25% and 80%.
The preset or actual humidity is indicated by
the number of LEDs which light up on the
humidity LED wheel c. The more LEDs light
up, the higher the humidity is. An additional
LED is equivalent to an increase of 5%.
The maximum humidity level which can
be set depends on the temperature of the
sauna. The higher the sauna temperature,
the lower the maximum humidity level which
can be set.
After setting the preset humidity, this LED
remains active. This LED goes out when the
preset humidity has been reached (excep-
tion: timed humidity operation).

9.5. Power level display

If the dimmer switch function is activated for the device (see 8. Starting up),
you can adjust the power of the light and the fan from power level 1 to power
level 8. The power of the additional device can be adjusted from power level 1
to power level 7.
The power level selected is indicated by the number of LEDs which light up in
the power level display 3.
Power level 1 has the lowest power level and is indicated by the one LED which
lights up in the power level display 3.
Power level 7 or 8 is equivalent to the highest power level and is indicated by
the 7 or 8 LEDs that light up in power level display 3.
In addition, the power level display 3 is used for displaying errors. The number
of LEDs that flash in the power level display 3 in the event of an error indicate
the error number.
Humidity
Number of
LEDs lit
1
2
3
4
5
6
7
8
9
10
11
12
p. 33/46
%
≤ 25
30
35
40
45
50
55
60
65
70
75
80