Herunterladen Inhalt Inhalt Diese Seite drucken

Connecting The Foil Sensor (Optional); Status Output; Finishing Installation - Harvia SENTIO just sauna combi weiß Gebrauchs- Und Montageanleitung

Saunasteuerung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Installation instructions, only for experts
3. Connect the wires for the humidity sensor to the terminals labelled "+ S -"
in terminal strip 2.
c. Connect the green wire to terminal "+".
d. Connect the orange wire to terminal "S".
e. Connect the red wire to terminal "-".

5.10. Connecting the foil sensor (optional)

1. Guide the wires for the sensor through the cable bushing 5 into the low-
voltage connection area 1.
2. Connect the wires for the sensor to the terminals labelled "FF" in terminal
strip 2.

5.11. Status output

Any electrical device can be connected to the status output terminal which is
suitable for 24 V DC voltage and draws a current no greater than 200 mA.
Make sure the polarity is correct when connecting a device. When LEDs are
used, a suitable series resistor must be used.

5.12. Finishing installation

1. Connect the earth conductor for the power supply cable and all devices to
the earth rail h.
2. Place the cover of the housing on the upper edge of the junction box.
3. Push the clip locks inwards lightly, and turn the cover of the housing down-
wards until it engages audibly.
p. 23/46