Herunterladen Inhalt Inhalt Diese Seite drucken

Installing The Humidity Temperature Sensor Fts2 (Optional) - Harvia SENTIO just sauna combi weiß Gebrauchs- Und Montageanleitung

Saunasteuerung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Installation instructions, only for experts
2. Pull the two half-shells of the bench sensor apart.
3. Connect the two connectors for the bench sensor wire to the two middle
terminals on the connection panel.
4. Place the connection panel crossways in the bench sensor half-shells.
5. Place the two half-shells together and screw them together using the two
cross-head screws (9 mm).
6. Check whether the bench sensor has been securely closed.
7. Install the bench sensor on the wall of the sauna room using the two
wood screws enclosed (16 mm). Maintain a gap of 15 cm to the roof of the
sauna room.

4.5. Installing the humidity temperature sensor FTS2 (optional)

The humidity temperature sensor must be installed on the wall of the sauna room
above the rear bench seat. A distance of approx. 15 cm to the roof of the sauna
must be maintained.
To install the humidity temperature sensor, perform the following steps:
1. Lay the two 5-pin bench sensor wires in the wall of the sauna room, leading
them to the humidity temperature sensor installation location and affix the
sensor wires using wire clips.
2. Install the humidity temperature sensor to the wall of the sauna room using
the two wood screws enclosed (16 mm). Maintain a gap of 15 cm to the
roof of the sauna room.
p. 17/46
EN

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Sentio just sauna combi schwarz

Inhaltsverzeichnis