3.3.1. Electric Heater Insulation Resistance

When performing the final inspection of the electrical
installations, a "leakage" may be detected when
measuring the heater's insulation resistance. The
reason for this is that the insulating material of the
heating elements has absorbed moisture from the
air (storage, transport). After operating the heater
for a few times, the moisture will be removed from
the heating elements.
Do not connect the power feed for the heater
through the RCD (residual current device)!

3.4. Installing the Heater

See figure 8.
1. Connect cables to the heater ( 3.3.).
2. Place the heater and adjust the heater vertically
straight using the adjustable legs.
1.
3.3.
3. a
3. b
Figure 8.
Installing the heater
Abbildung 8. Installation des Saunaofens
DE

3.3.1. Isolationswiderstand des Elektrosaunaofens

Bei der Endkontrolle der Elektroinstallationen kann
bei der Messung des Isolationswiderstandes ein
"Leck" auftreten, was darauf zurückzuführen ist,
dass Luftfeuchtigkeit in das Isolationsmaterial der
Heizwiderstände eingetreten ist (bei Lagerung und
Transport). Die Feuchtigkeit entweicht aus den Wi-
derständen nach zwei Erwärmungen.
schalter ein!

3.4. Installation des Saunaofens

Siehe Abb. 8.
1. Verbinden Sie die Kabel mit dem Ofen ( 3.3.).
2. Richten Sie den Ofen mit den verstellbaren
Füßen lotrecht aus.
3. Bringen Sie den Ofen mit Befestigungssätzen (2
Stück) an der Saunakonstruktion an.