Herunterladen Inhalt Inhalt Diese Seite drucken

2-Cycle And 4-Cycle Interval With Wire Retraction - Abicor Binzel ABIDRIVE 2 Betriebsanleitung

Wig kaltdrahtvorschub
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6 Putting into operation
Setting the torch triggers
Function F5 can be used to configure rockers T1 and T3 (2):
Left display
F5
Tab. 12

6.4.2 2-cycle and 4-cycle interval with wire retraction

(infinitely adjustable, continual forwards and backwards movement)
This interval mode is switched on using function F7 (ON).
The function tof stops the wire feed for the preset period.
The wire feed rate is set using the function SPE.
The wire retraction feed rate is set using function F2.
The applicable parameter settings can be found in the following table:
Function
Description
F7
Wire retraction mode
tof
Wire feed interval break
SPE
Wire feed rate
F2
Wire retraction feed rate
Tab. 13
Wire retraction settings
2T
Interval
F7=OFF
Interval
F7=ON
Fig. 10
Example of interval functions
EN - 16
Right display
A
T1 = wire feed
T3 = wire retraction
b
T1 = increases the wire feed rate in standby mode during welding
T3 = reduces the wire feed rate in standby mode during welding
C
T1 = wire feed and increases the wire feed rate in standby mode during
welding
T3 = wire retraction and reduces the wire feed rate in standby mode during
welding
Setting the rocker
Explanation of the setting process
 Tab. 10 Display indicators for advanced functions on page EN-14
 Tab. 9 Display indicators after switching on on page EN-12
 Tab. 9 Display indicators after switching on on page EN-12
 Tab. 10 Display indicators for advanced functions on page EN-14
t1
ton
tof
dt
ton
dt
tof
TIG cold-wire feeder
T2
t2
m/min
Motor
rE
m/min
Motor
rE

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis