Herunterladen Inhalt Inhalt Diese Seite drucken

21 6. Technical Data 6.1 Kts; 6.2 Interface Protocols; 21 6.3 Power Pack; 21 6.4 Multimeter Specification - Bosch KTS 650 Betriebsanleitung

Systemtester steuergerätediagnose
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
6.
Technical data
6.1
KTS 650
Property
Main memory
Hard disk
Display
Battery
Operating voltage via
vehicle battery or power pack
Power consumption
Dimensions (L x W x H)
Weight (without
connection cables)
Operating temperature
6.
Interface protocols
Control unit diagnostics via the interface protocols
ISO 9141-2, SAE J1850VPW, SAE J1850PWM and CAN
ISO 11898, ISO 15765-4 (OBD), OBD diagnostics accor-
ding to ISO 15031.
6.
Power pack
Property
Input voltage
Input frequency
Output voltage
Operating temperature
6.4
Multimeter specification
Measuring channel 1 (CH1)
Measuring channel 2 (CH2)
6.4.1
DC measurement (CH1 and CH)
Property
Measurement range
Precision
Resolution
Bosch Diagnostics
Value/range
518 MB
40 GB
TFT 12" color
800 x 600 pixel
Lithium-ionic, 7.2 V; 6 Ah
10 V – 30 V DC
approx. 40 W
300 x 400 x 125 mm
4200 g
0 °C – 40 °C
Value/range
90 V AC – 264 V AC
47 Hz – 63 Hz
15 V
0 °C – 40 °C
zero potential
potential based
Value/range
0 – 200 V, automatic ranging
± 0.75 % of reading,
plus
± 0.25 % of measurement
range
100 µV –100 mV
(depending on measurement
range)
Technical data | KTS 650 | 9
6.4.
AC and effective value measurement (CH1 and
CH)
Property
Frequency range AC
Measurement range
Precision
Resolution
6..

Resistance measurement (CH1)

Property
Measurement range
Precision
Resolution
6..4
Current measurement (CH1 and CH)
Property
100 A clamp
600 A clamp
Shunt (only CH1)
General
input resistance
Diode test
6.5

Oscilloscope specification

Property
Measurement range
Coupling
Signal source
Trigger mode
Trigger source
 deflection
From 1 second time deflection, the oscilloscope is ope-
rated in roll mode.
Property
Y deflection at U
Y deflection at 600A current
clamp (1 mV/A)
Y deflection at 100A current
clamp (1 mV/A)
Y deflection at 600 mA shunt
en
Value/range
5 Hz – 400 Hz
0 – 200 V, automatic ranging
± 3 % of reading,
plus
± 0.25 % of measurement
range
100 µV – 100 mV
(depending on measurement
range)
Value/range
0.1
– 1 M
, automatic ran-
ging
± 0.75 % of reading,
plus
± 0.25 % of measurement ran-
ge
0.1
– 1000
(depending on measurement
range)
Value/range
-100 A – 100 A
-600 A – 600 A
0 – 600 mA
1.5 M
Test voltage max. 2 V;
Test current < 2 mA
Value/range
0 – 200 V
DC, AC
U, I-clamp I-shunt
Standard, Auto, Auto-
threshold
CH1, CH2
5 ms – 100 s
Value/range
200 mV – 200 V
200 A, 500 A, 600 A
20 A, 50 A, 100 A
200 mA, 500 mA, 600 mA
1 689 979 856
|
2007-05-04

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading