9.3. Material hopper

The pump shaft rotates during operation!
Rotating shaft!
Risk of fatal injury from drawing in and crushing!
• Do not reach into the container

9.4. Pump unit

9.4.1. Plaster pressure gauge
Plaster pressure gauge
The plaster pressure gauge is used to monitor the delivery
pressure. It is mandatory according to safety regulations.
Overpressure!
Risk of injury from bursting delivery hoses!
• Continuously check the delivery pressure at the pressure
gauge!
• Immediately relieve the pressure through return flow,
and switch off the machine immediately if the delivery
pressure exceeds 16 bar!

9.4.2. Pump shaft

The pump shaft rotates during operation.
Rotating shaft!
Risk of fatal injury from drawing in and crushing!
• Do not reach into the rotating shaft!
• Do not push solid objects into the rotating shaft!
Observe the notes in the chapters:
• Installation.
• Cleaning.
• Maintenance and care.
• Malfunctions, cause and elimination.

9.5. Drive unit

Electrical voltage!
Risk of fatal injury due to electric shock.
• Work on the drive control unit must be carried out by
a professional workshop! Contact STORCH Service: (+49
800) 7 86 72 47 (free of charge in Germany).
Observe the instructions in the chapter:
• Malfunctions, cause and elimination.