Warning
2.1
Preparatory measures
2.2
Secure customer parameterization
The customer parameterization determines the behaviour and the function of the inverter/ser-
vo. Possibly the parameterisation can be overwritten by changing the interface card. There-
fore, it is generally advisable to make a backup of the customer parameterisation.
Switch on unit
Store customer parameters
Switch off and discharge
Secure against restarting
Start modification
Restore customer parameter
Do not open any electrical connections
No internal electrical connections may be opened during installation or
changing of the encoder interface. The certification for "functional safety"
expires in case of contravention. The opening of electrical connections with
the following required tests is only permissible of authorized personnel by
Karl E. Brinkmann GmbH.
Start up the unit with mains voltage or use external supply
of the control with 24 Vdc.
↓
Store customer parameterization with COMBIVIS.
↓
Disconnect the device from mains and wait until the inter-
mediate circuit is discharged.
↓
The application must be secured against restarting during
work.
↓
↓
Restore customer parameterization with COMBIVIS.Even-
tually new parameterization of the new encoder interface.
Safety Instructions
GB -9