Herunterladen Inhalt Inhalt Diese Seite drucken

Operating Incidents - jbc Advanced TE 5400 Instruktionshandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 35
ENGLISH
MAINTENANCE
Changing the heater.
Use a wrench to unscrew the cover.
Move back the spring and the cover. Pull the
connector from the socket to disconnect the heater
from the station.
O-ring ø17 x ø1,8
Follow this process inverted to re-connect the
heater.

OPERATING INCIDENTS

The suction cup does not adhere to the
component.
Deficient aspiration, Vacuum.
1 Verify if the suction cup is well placed and in
perfect condition.
2 Check the incoming air filter in the interior of
the station and replace it if dirty or
obstructed.
Filter
Ref. 0861800
Error messages
Whenever the ERR message appears, the
equipment turns itself off completely.
The following messages are displayed:
- BLANK SCREEN
Power failure.
Check for blown fuses.
- ERR 1
The temperature will not rise.
Possible causes:
· Heating element open.
· In case of a long low-power period.