Technical Data

13
Technical Data
Parameter
Measured variable:
Field of application:
Measuring ranges:
pH-range:
Temperature range:
Storage temperature:
Dissolution:
Maximum operating
pressure:
Flow:
Cross-sensitivity:
Service life of the dia‐
phragm cap:
Material:
Supply voltage:
Output signal:
Degree of protection:
68
Value
Chlorine dioxide (ClO
CDE 2: Potable water and water of similar quality, surfactant-free.
CDE 3: as CDE 2 but up to 60 °C.
CDE 2-mA-0.5 ppm: 0.01 ... 0.5 mg/l, standard slope: 24 mA/ppm.
CDE 2-mA-2 ppm: 0.02 ... 2 mg/l, standard slope: 6 mA/ppm.
CDE 2-mA-10 ppm: 0.1 ... 10 mg/l, standard slope: 1.2 mA/ppm.
CDE 3-mA-0.5 ppm 0.01 ... 0.5 mg/l, standard slope: 24 mA/ppm.
4.0 ... 11.
5 ... 45 °C (temperature-compensated). No sudden changes in tem‐
perature.
5 ... 50 °C.
corresponds to the lower measuring range limit.
DGM: 1.0 bar (free flow), no negative pressure.
DLG III: 1.0 bar (free flow), no negative pressure.
Bypass fitting DLG III A/B / DGM.
Optimum: 60 ... 80 l/h; at least: 40 l/h; maximum: 120 l/h.
O
and chlorine < 2%.
3
Ø 1 year, depending on the water quality.
The presence of agents decreasing the surface tension (surfactants)
can significantly reduce the service life. ProMinent offers a surfactant-
proof sensor type CDP 1-mA-2 ppm.
CDE 2: Diaphragm cap, PVC, clear.
CDE 3: Diaphragm cap, PMMA.
CDE 2: Sensor shaft, PVC, black and PMMA, colourless.
CDE 3: Sensor shaft, PVC-C.
16 ... 24 V DC.
4 ... 20 mA.
IP 65.
).
2