Herunterladen Inhalt Inhalt Diese Seite drucken

Deleting Minimum/Maximum Values; Switching Between Several Temperature/Air Humidity Sensors; Automatic Switching In Case Of Several Temperature/Air Humidity Sensors; Selecting Or Turning The Temperature Alarm On/Off - Conrad DV928 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

     Deleting minimum/maximum values
• First, briefly press the button "MEMORY" (17) to display the minimum and maximum values.
• Now keep the button "MEMORY" (17) depressed for approx. 3 seconds. This deletes the minimum and maximum
values.
Until the next value change, the current values for temperature and air humidity are saved as minimum
resp. maximum values.
     Switching between several temperature/air humidity sensors
• Briefly press the button "CHANNEL" (4) to select the desired outdoor sensor for the temperature/air humidity. The
corresponding channel number is displayed.
If you only use one temperature/air humidity sensor, you must set this to "Channel 1" (switch in the
sensor's battery compartment), otherwise the progression display does not work (see chapter 13 a,
section "View progression of the temperature or air humidity in the past 24 hours").
     Automatic switching in case of several temperature/air humidity sensors
If you operate more than one temperature/air humidity sensor, the weather station can also change the up to 5
channels automatically.
• Keep the button "CHANNEL" (4) depressed until the symbol "
This is only possible if more than one temperature/air humidity sensor is registered with the weather
station; otherwise no symbol appears.
• To deactivate the automatic switchover again, keep the button "CHANNEL" (4) depressed until the symbol "
disappears.
     Selecting or turning the temperature alarm on/off
For each of the 5 channels, you can select a top and bottom temperature. When this is exceeded or undercut, an
alarm sounds (stop this by pressing the button "ALARM/CHART" (10)).
• First select the desired channel for the corresponding temperature/air humidity sensor with the button "CHANNEL"
(4), for which you want to select resp. deactivate the temperature alarm.
• Briefly press the button "ALARM/CHART" (10) repeatedly to switch between the top temperature limit (symbol
"
"), bottom temperature limit (symbol "
• If the symbol "
" or "
briefly pressing the button " " (16) or " " (18) on the rear.
When the temperature alarm is deactivated, the display shows "OFF"; when it is activated, the
respective value.
     Setting the temperature values for the temperature alarm
• First press the button "ALARM/CHART" (10) once or twice to display the top (symbol "
temperature alarm. Then briefly press the button " " (16) or " " (18) on the rear to activate the temperature alarm
(a temperature value is displayed instead of "OFF").
• Now keep the button "ALARM/CHART" (10) depressed until the temperature value changes.
• You can change the temperature value with the buttons " " (16) or " " (18) on the rear (keep the respective button
depressed longer for quick adjustment).
• Save the setting by briefly pressing the button "ALARM/CHART" (10).
") and the normal display.
" is displayed, you can activate or deactivate the corresponding temperature alarm by
" appears.
") or bottom (symbol "
"
")
87