b) Function "Temperature/air humidity" (symbol "
In the basic display mode of the weather station, select the function "Temperature/air humidity with the
button " " (6) or " " (7). The corresponding symbol (see above) blinks.
The following setting options and displays are available now:
 Switching the display unit °C/°F
• Keep the button "SET" (5) depressed until the display unit (°C/°F) for the indoor/outdoor temperature is switched.
• Release the button again.
 Dew point display
• Briefly press the button "SET" (5); "DEW" (= dew point) is displayed on the top right between the values, and the
temperature display is switched.
• If you briefly press the button "SET" (5) once again, the current temperature is displayed again.
The so-called dew point is a temperature point that depends on the concurrence of a certain air
pressure, a certain temperature and a certain air humidity.
Condensation of the air humidity starts at this point and condensation turns into liquid (fog, mist).
If the dew point for steam is below 0°C, condensation takes place in the shape of snow or frost.
 Display of the minimum/maximum values for temperature/air humidity
• First select the desired temperature/air humidity sensor with the button "CHANNEL" (4).
• Briefly press the button "MEMORY" (3). "MIN" appears between the temperature/air humidity values and the
minimum values are displayed.
• Briefly press the button "MEMORY" (3) again; "MAX" appears and the maximum values are displayed.
• With another brief press of the button "MEMORY" (3), the display changes to the current measuring values.
 Deleting minimum/maximum values
• First, briefly press the button "MEMORY" (3) to display the minimum and maximum values.
• Now keep the button "MEMORY" (3) depressed for approx. 3 seconds. This deletes the minimum and maximum
values.
Until the next value change, the current values for temperature and air humidity are saved as minimum
resp. maximum values.
 Switching between several temperature/air humidity sensors
• Briefly press the button "CHANNEL" (4) to select the desired outdoor sensor for the temperature/air humidity. The
corresponding channel number is displayed.
If you only use one temperature/air humidity sensor, you must set this to "Channel 1" (switch in the
sensor's battery compartment), otherwise the progression display does not work (see chapter 12 a,
section "See progression of the temperature or air humidity in the past 24 hours").