9. EXPLOSIONSGESCHÜTZTE AUSFÜHRUNGEN

9.2.4 Ex-relevante Kennzeichnungen auf den Typenschildern (s. Kapitel 3.11)

RCCT3 Option /FF1, /FF2 oder /FF5:
Control Drawing No. 8300026
Class I, Division 1; Group A, B, C, D
Class II / III, Division 1, Group E, F, G
AEx d [ia] IIC, Class I, Zone 1, T6
Conduit Seals required within 18 inches.
Use Conductors rated 70°C
TYPE NEMA 4X, IP67
WARNUNG
WAIT 15 MIN. AFTER POWER-DISCONNECTION
BEFORE OPENING THE ENCLOSURE.
RCCF31 Option /FF1, /FF2 oder /FF5:
Control Drawing No. 8300027
Class I, Division 1; Group A, B, C,D
AIS Class I / II / III, Division 1, Group A, B, C, D, E, F, G
Class II / III, Division 1, Group E, F, G
AEx d [ia] IIC, Class I, Zone 1, T6
Conduit Seals required within 18 inches.
Use Conductors rated 70°C
TYPE NEMA 4X, IP67
WARNUNG
WAIT 15 MIN. AFTER POWER-DISCONNECTION
BEFORE OPENING THE ENCLOSURE.
RCCR31 Option /FS1:
Control Drawing No. 8300028
AIS Class I , Division 1, Group A, B, C, D
AEx [ia] IIC, Class I, Zone 1
RCCT3 Option /FF1 + /DS:
Control Drawing No. 8300026
Class I, Division 1; Group A, B, C, D
Class II / III, Division 1, Group E, F, G
AEx d [ia] IIC, Class I, Zone 1, T6
Conduit Seals required within 18 inches.
Use Conductors rated 70°C
TYPE NEMA 4X, IP67
WARNUNG
WAIT 15 MIN. AFTER POWER-DISCONNECTION
BEFORE OPENING THE ENCLOSURE.
Dual Seal
RCCS3 Option /FS1:
Control Drawing No. 8300027
IS Class I, Division 1; Group A, B, C, D, T6
Class II / III, Division 1, Group E, F, G
AEx ia IIC, Class I, Zone 0
Use Conductors rated 20°C above max. ambient
temperature
TYPE NEMA 4X, IP67
Temperature Class see Control Drawing
IM 01R04B04-00D-E
10. Ausgabe 1. Oktober, 2013 -00
RCCT3 Option /FF1, /FF2 oder /FF5 + /HP:
Control Drawing No. 8300026
Class I, Division 1; Group C, D
Class II / III, Division 1, Group E, F, G
AEx d [ia] IIB, Class I, Zone 1, T6
Conduit Seals required within 18 inches.
Use Conductors rated 70°C
TYPE NEMA 4X, IP67
WARNUNG
WAIT 15 MIN. AFTER POWER-DISCONNECTION
BEFORE OPENING THE ENCLOSURE.
RCCF31 option /FF1, /FF2 oder /FF5 + /HP:
Control Drawing No. 8300027
Class I, Division 1; Group C, D
AIS Class I / II / III, Division 1, Group C, D, E, F, G
Class II / III, Division 1, Group E, F, G
AEx d [ia] IIB, Class I, Zone 1, T6
Conduit Seals required within 18 inches.
Use Conductors rated 70°C
TYPE NEMA 4X, IP67
WARNUNG
WAIT 15 MIN. AFTER POWER-DISCONNECTION
BEFORE OPENING THE ENCLOSURE.
RCCR31 Option /FS1 + /HP:
Control Drawing No. 8300028
AIS Class I , Division 1, Group C, D
AEx [ia] IIB, Class I, Zone 1
RCCT3 Option /FF1 + /HP + /DS:
Control Drawing No. 8300026
Class I, Division 1; Group C, D
Class II / III, Division 1, Group E, F, G
AEx d [ia] IIB, Class I, Zone 1, T6
Conduit Seals required within 18 inches.
Use Conductors rated 70°C
TYPE NEMA 4X, IP67
WARNUNG
WAIT 15 MIN. AFTER POWER-DISCONNECTION
BEFORE OPENING THE ENCLOSURE.
Dual Seal
RCCS3 Option /FS1 + /DS:
Control Drawing No. 8300027
IS Class I, Division 1; Group A, B, C, D, T6
Class II / III, Division 1, Group E, F, G
AEx ia IIC, Class I, Zone 0
Use Conductors rated 20°C above max. ambient
temperature
TYPE NEMA 4X, IP67
Temperature Class see Control Drawing
Dual Seal
9-14