9.2.5 Control drawings

Hazardous Locations :
Class I Division 1 Groups A,B,C,D or Class I Zone 1 Group IIC
Class I Division 1 Groups C,D or Class I Zone 1 Group IIB (option /HP)
and Class II and III Division 1 Groups E,F,G
Temperature classification :
Temp.
RCCT34 to RCCT39/XR
class
Max.
Ambient
temperature
T6
≤ 50°C / 122°F ≤ 65°C / 149°F
T5
≤ 50°C / 122°F ≤ 80°C / 176°F
T4
≤ 50°C / 122°F ≤ 115°C / 239°F
≤ 50°C / 122°F ≤ 150°C / 302°F
T3
The minimum ambient temperature is -40°C / -40°F
Installation :
HAZARDOUS LOCATION
Rotamass RCCT3
Note :
-
For AC-version maximum power supply is 250V AC.
-
For DC-version maximum power supply is 28.8V DC.
-
The installation must be in accordance with the national electrical code, NFPA70, article 504 to 510
and ANSI/ISA RP 12.06.01.
-
The non intrinsically safe terminals must not be connected to any device that uses or generates more
than 250Vrms or dc unless it has been determined that the voltage was adequately isolated.
-
Installation must be in accordance with the Canadian Electrical Code, when installed in Canada.
WARNING : Substitution of components may impair intrinsic safety.
c
---------- 5.3.07 Butz
b
---------- 1.9.05 Butz
a
UPDATE No.
Rev.
DATE
All Rights Reserved. Copyright © 2003, Rota Yokogawa
Max.
Medium
temperature or
temperature of
heat carrier
DATE
09.02.2005
DRAWED
09.02.2005 Rü
CKECKED
YOKOGAWA
79664 WEHR
GERMANY
EDITOR CHECKED
9. EXPLOSIONSGESCHÜTZTE AUSFÜHRUNGEN
NPT 1/2"
L/+
N/-
G
I/O
NAME
TITEL:
Butz
FM/CSA CONTROL DRAWING
ROTAMASS RCCT3
DWG. No.:
8300026
9-15
IM 01R04B04-00D-E
NON HAZARDOUS LOCATION
Power supply
I/O control