9. EXPLOSIONSGESCHÜTZTE AUSFÜHRUNGEN

9.1.5 Ex-relevante Kennzeichnungen auf den Typenschildern (s. Kapitel 3.11)

RCCT3 Option /KF1:
KEMA 02 ATEX 2183X
II 2 G Ex d ib IIC T6...T3 Gb or
II 2 G Ex d e ib IIC T6...T3 Gb
II 2 D Ex ib tb IIIC T150°C Db
DIODE SAFETY BARRIER Um : 250Vac/dc
TEMP. CLASS
PROCESS TEMP.
ENCLOSURE: IP67
SEE CERTIFICATE FOR DATA
WARNUNG
WAIT 15 MIN. AFTER POWER-DISCONNECTION
BEFORE OPENING THE ENCLOSURE.
RCCT3 Option /KF2 und /KF5:
KEMA 02 ATEX 2183X
II 2 (1) G Ex d ib [ia Ga] IIC T6...T3 Gb or
II 2 (1) G Ex d e ib [ia Ga] IIC T6...T3 Gb
II 2 (1) D Ex ib tb [ia Da] IIIC T150°C Db
DIODE SAFETY BARRIER Um : 250Vac/dc
TEMP. CLASS
PROCESS TEMP.
ENCLOSURE: IP67
SEE CERTIFICATE FOR DATA
WARNUNG
WAIT 15 MIN. AFTER POWER-DISCONNECTION
BEFORE OPENING THE ENCLOSURE.
RCCF31 Option /KF1:
KEMA 02 ATEX 2183X
II 2 G Ex d [ib] IIC T6 Gb or
II 2 G Ex d e [ib] IIC T6 Gb
II 2 D Ex tb [ib] IIIC T75°C Db
DIODE SAFETY BARRIER Um : 250Vac/dc
ENCLOSURE: IP67
SEE CERTIFICATE FOR DATA
WARNUNG
WAIT 15 MIN. AFTER POWER-DISCONNECTION
BEFORE OPENING THE ENCLOSURE.
RCCF31 Option /KF2 und /KF5:
KEMA 02 ATEX 2183X
II 2 (1) G Ex d [ia Ga] [ib] IIC T6 Gb or
II 2 (1) G Ex d e [ia Ga] [ib] IIC T6 Gb
II 2 (1) D Ex tb [ia Da] [ib] IIIC T75°C Db
DIODE SAFETY BARRIER Um : 250Vac/dc
ENCLOSURE: IP67
SEE CERTIFICATE FOR DATA
WARNUNG
WAIT 15 MIN. AFTER POWER-DISCONNECTION
BEFORE OPENING THE ENCLOSURE.
IM 01R04B04-00D-E
10. Ausgabe 1. Oktober, 2013 -00
T6 T5 T4 T3
65 80 115 150°C
T6 T5 T4 T3
65 80 115 150°C
RCCT3 Option /KF1 + /HP:
KEMA 02 ATEX 2183X
II 2 G Ex d ib IIB T6...T3 Gb or
II 2 G Ex d e ib IIB T6...T3 Gb
II 2 D Ex ib tb IIIC T150°C Db
DIODE SAFETY BARRIER Um : 250Vac/dc
TEMP. CLASS
PROCESS TEMP.
ENCLOSURE: IP67
SEE CERTIFICATE FOR DATA
WARNUNG
WAIT 15 MIN. AFTER POWER-DISCONNECTION
BEFORE OPENING THE ENCLOSURE.
RCCT3 Option /KF2 und /KF5 + /HP:
KEMA 02 ATEX 2183X
II 2 (1) G Ex d ib [ia IIC Ga] IIB T6...T3 Gb or
II 2 (1) G Ex d e ib [ia IIC Ga] IIB T6...T3 Gb
II 2 (1) D Ex ib tb [ia Da] IIIC T150°C Db
DIODE SAFETY BARRIER Um : 250Vac/dc
TEMP. CLASS
PROCESS TEMP.
ENCLOSURE: IP67
SEE CERTIFICATE FOR DATA
WARNUNG
WAIT 15 MIN. AFTER POWER-DISCONNECTION
BEFORE OPENING THE ENCLOSURE.
RCCF31 Option /KF1 + /HP:
KEMA 02 ATEX 2183X
II 2 G Ex d [ib] IIB T6 Gb or
II 2 G Ex d e [ib] IIB T6 Gb
II 2 D Ex tb [ib] IIIC T75°C Db
DIODE SAFETY BARRIER Um : 250Vac/dc
ENCLOSURE: IP67
SEE CERTIFICATE FOR DATA
WARNUNG
WAIT 15 MIN. AFTER POWER-DISCONNECTION
BEFORE OPENING THE ENCLOSURE.
RCCF31 Option /KF2 und /KF5 + /HP:
KEMA 02 ATEX 2183X
II 2 (1) G Ex d [ia IIC Ga] [ib] IIB T6 Gb or
II 2 (1) G Ex d e [ia IIC Ga] [ib] IIB T6 Gb
II 2 (1) D Ex tb [ia Da] [ib] IIIC T75°C Db
DIODE SAFETY BARRIER Um : 250Vac/dc
ENCLOSURE: IP67
SEE CERTIFICATE FOR DATA
WARNUNG
WAIT 15 MIN. AFTER POWER-DISCONNECTION
BEFORE OPENING THE ENCLOSURE.
9-8
All Rights Reserved. Copyright © 2003, Rota Yokogawa
T6 T5 T4 T3
65 80 115 150°C
T6 T5 T4 T3
65 80 115 150°C

Werbung