Herunterladen Inhalt Inhalt Diese Seite drucken

Conditions Of Use And Installation - WMF combiNation F 8700 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6 Conditions of use and installation

The machine operator must arrange for the site preparatory work. This should be carried out by
approved contractors in accordance with general and local regulations. WMF customer service
technicians are only permitted to connect the machine to the prepared connections. They are not
authorised to carry out plumbing or wiring work on site and will not be responsible for such
work.
Rated power
Connecting cable, site supply *
Fuse, site supply
Mains voltage tolerance
Water feed line
Water quality
Water drain line
Ambient temperature
Max. humidity
Protection
Installation clearance
Water filter installation
dimensions
W × H × D
* The site electrical system must comply with IEC 364. For greater safety, an earth leakage circuit breaker with a
rated fault current of 30 mA to EN 61008 should be fitted in the supply line to the machine. In the vicinity of the
machine, for a single-phase connection a shockproof socket and for a three-phase connection a 5-pole
CEE/CEKON socket to EN 60309 should be fitted. If the power lead to this machine is damaged, it must be
replaced by WMF customer service or a similarly qualified specialist. If the machine is permanently connected
on site, an all-pole circuit breaker (main switch) to EN 60947 with not less than 3 mm contact opening should
preferably be fitted ahead of the machine. In the case of a flexible connection, the circuit breaker is
recommended. The power lead must not be allowed to come into contact with hot components. The main switch
and socket are part of the customer's system. The machine must not be installed with a fixed site connection if
used with a trolley (mobile station).
84
9.3 kW
2
5 × 2.5
3 × 16 A
230 V/400 V + 6 % - 10 %
Power cut < 50 ms does not affect machine operation
TW15 (DN 15 /1/2") with dirt filter installed by customer,
min. 0,2 MPa flow pressure at 8 l/min, max. 0,6 MPa
If the local water has a carbonate hardness over 9°, a
WMF water filter must be fitted in the supply line.
Min. DN 40 (1 ½"), minimum gradient 2 cm/m
+ 5°C to + 35°C (drain water system in case of frost)
80 % rel. humidity without dewing; do not spray
machine with water; do not use machine out of doors.
For operating, service and safety reasons the machine should
be installed with clearance of not less than 50 mm from the
back and sides from the building or non-WMF components.
A clear height of 1100 mm from the top of the supporting
surface should be ensured. The height of the supporting
surface from the floor surface should be not less than
700 mm and not more than 900 mm.
If the machine connections are to be routed down through
the counter, remember also to allow space for the
connections. These may restrict the available space below
the machine.
Standard:
250 × 500 × 400 mm
Jumbo:
290 × 670 × 420 mm
13.8 kW
5 × 4²
3 × 25 A
IP 30