Monoblocco 400 Piano – 500 / 800 Angolo

7.1. EXTERNAL AIR INTAKE

There MANDATORY be sufficient quantity of air for combustion and re-oxygenation of the room to ensure the device
will work properly. There should therefore be vents letting air in from
outside the building and enabling circulation of air for combustion even
when the doors and windows are closed Picture 18.
The air intake must be in a position where it cannot be
obstructed.
The air intake should communicate with the room in which the
device is installed and be protected with a grille.
Vents may communicate with adjacent rooms but not with
garages, kitchens, bathrooms or boiler rooms.
Any extractor hoods in the room where the device is installed
must not operate at the same time as this could cause smoke to
enter the room, even with the fireplace's door closed.
Minimum dimensions Picture 18:
A – natural convection: 300 cm
B – forced convection:
2
150 cm
external air intake for the stack (*B1);
2
150 cm
external air intake for the fan (B2);
2
150 cm
internal air intake for the fan (C-mod.800 angolo);
For a better comfort and corresponding oxygenation of environment, the combustion air can be directly withdrawn at
* (
the outside through a junction (B1) which is to be connected with a flexible pipe (not furnished)for the external air
intake. The connection pipe must be flat with a minimum diameter of 120mm mod.500 - 100mm mod.800, a maximum
length of 4 m and with no more than 3 bends. If there is a direct connection with the outside it must be endowed with
a special windbreak.
)
8.

CONNECTION AND MAINTENANCE OF VENTILATION

The control unit and system must be installed and connected by a skilled worker according to regulations in
force (see chap.1).
ATTENTION: the feeding cable must not be in contact with hot parts.
Our fireplaces (mod.500 e 800) can be fitted with ventilation OPTIONAL kits to improve the distribution of heat by
means of ventilation in the room in which the fireplace is installed or of the adjacent room (see chap.7).
Follow the instructions on how to install the OPTIONAL ventilation kit (see chap. 19).
The kit comprises a centrifugal fan, a start-up control unit and a thermostat that starts up the fan when the device is
sufficiently heated and stops it when it is cool.
MANDATORY:
cable out of seeing!
Picture 19
designed. The manufacturer cannot assume any liability for improper use.
6098401 – EN
2
POWER SUPPLY
DIMENSIONS
CONTAINER
CONNECTION: Connect the power supply cable of the
control unit to a bipolar switch respecting at least a 3 mm
distance between the contacts (230 V~ 50 Hz power
supply; it is also essential that the system is properly
earthed).
WARNING: The CONTROL must be connected to the
mains with a differential line cut-off switch according
to regulations in force. The control only works
properly with the special motor for which it was
B1
B2
A
B1
CARATTERISTICHE TECNICHE
230 V~ +15 – 10% 50/60 Hz
120 x 74 x 51 mm
Self-extinguishing ABS IP40 V0
TM
Thermostat
A
C
Picture 18