Herunterladen Inhalt Inhalt Diese Seite drucken

Nordica MONOBLOCCO 400 PIANO Dx Gebrauchshandbuch Seite 22

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

50 cm
2 m
1
m
CHIMNEY CAPS – DIST ANCES AND PO SIT IO NING UNI 10 683 /9 8
Roof inclination
α
15°
30°
45°
60°
22
In the case of flues installed next to each other, there should be a
difference of at least 50 cm in height between each chimney cap to
avoid transfer of pressure between the flues
10 m
There must be no obstructions, such as walls, pitches and
trees, within 10 metres from the chimney cap. Otherwise,
the chimney cap must be raised at least 1 metres above the
obstacle. The chimney cap must stand at least 1 m above
the ridge of the roof.
>A
Min H.
(1)Ridge axis
α
Distance between roof
ridge and stack
A (m)
< 1.85 m
> 1.85 m
< 1.50 m
> 1.50 m
< 1.30 m
> 1.30 m
< 1.20 m
> 1.20 m
Monoblocco 400 Piano – 500 / 800 Angolo
> _ A
0.5 m
(2)Roof
Stack's minimum height (measured from
0.50 m above roof ridge
1.00 m from the roof
0.50 m above roof ridge
1.30 m from the roof
0.50 m above roof ridge
2.00 m from the roof
0.50 m above roof ridge
2.60 m from the roof
.
Picture 10
Picture 11
Picture 12
outlet)
H (m)