IMPORTANT
:
With the use of metal pipes, it is indispensable that they be insulated with a suitable material
(coverings in insulating fibre resistant up to 600°C) to prevent deterioration of the masonry or of
the counterplate.
It is indispensable that the space between the upper part, the sides of the appliance, and the incombustible
material deflector on the hood be constantly ventilated.
For this reason, there must be an air intake from below
(cool air inlet) and an outlet above (warm air outlet).
The spaces for air circulation indicated in Picture 13 are
the minimum requirements:
Top:
minimum opening 1000 cm2
Base:
minimum opening 750 cm2
This will provide:
greater safety
an increase of heat produced by the circulation of
air around the appliance.
Attention: We recommend making the counterplate in fire-
retardant plasterboard with self-supporting metal frame, so
that its weight does not bear on the aesthetic covering
(marble).
The heat breather grille (Picture 14 pos.6) is installed on
the upper part of the hood at about 20 cm from the ceiling.
It must always be installed, as its function is to allow the
heat accumulated inside the hood (overpressure) to come
into the room.
7. EXTERNAL
COMBUSTION
To ensure efficient operation of the appliance, it is essential that the place of installation has sufficient air
intake for combustion and for re-oxygenation of the room itself. This means that, by way of dedicated
openings communicating with the outside, combustion air must be able to circulate even when the doors
and windows are closed.
(1) Insulating material
(3) Insulating coating with external
(3) Rivestimento isolante provvisto
di foglio di alluminio esterno
aluminum sheet
(4) Door for cleaning
(4) Sportello per pulizia
(5) External air intake
(5) Presa aria esterna
(10) Min. distance between Coating
(10) Distanze posteriori e laterali
and insert min 6 cm
min 6 cm
28
AIR
INTAKE
(1) Isolante
(2) Seal
(2) Sigillare
IN
THE
INSTALLATION
Termocamino 650 - 800
6
min. 5 cm rear and lateral
Picture 13
AREA
(6) Heat drain grating
(6) Griglia sfiato calore
(7) Controcappa ignifuga
(7) Fire-retardant counter-hood
(8) Inclinazione massima 45°
(8) Maximum inclination 45°
(9) Schermare le parti in legno
(9) Shield wooden parts with
con materiale isolante
Instruction Manual – Rev.07 – EN
2
1000 cm
2
750 cm
DURING
Picture 14

Werbung