Verfügbare Sprachen

Temperature
Temperature
measurement
measurement
Temperature sensor
Temperature sensor
Accuracy
Accuracy
Resolution
Resolution
Inputs / outputs
Inputs / outputs
digital Interface
digital Interface
Sensor input
Sensor input
Contact outputs
Contact outputs
Signal outputs
Signal outputs
Connector terminals
Connector terminals
Protection type
Protection type
Lightning protector
Lightning protector
(inputs and outputs)
(inputs and outputs)
Electrical instrument
Electrical instrument
protection
protection
Housing
Housing
140
140
Technical data
Technical data
NTC
NTC
± 0.2 K ± 1 digit
± 0.2 K ± 1 digit
Additional fine adjustment of ± 0.5 K
Additional fine adjustment of ± 0.5 K
0.1 K
0.1 K
RS-485; 2(3)-wire connection bus operation with up to
RS-485; 2(3)-wire connection bus operation with up to
31 units is possible
31 units is possible
7-contact round plug connector with screw fixing
7-contact round plug connector with screw fixing
Relay 1/ Relay 2
Relay 1/ Relay 2
• max. switching voltage 250 VAC
• max. switching voltage 250 VAC
• max. switching current 5 A
• max. switching current 5 A
• max. switching capacity 150 W (ohmic load)
• max. switching capacity 150 W (ohmic load)
0/4 to 20 mA; electrically isolated from the input
0/4 to 20 mA; electrically isolated from the input
Recorder ranges and recorder attenuation can be set
Recorder ranges and recorder attenuation can be set
via software
via software
• Basic accuracy
• Basic accuracy
• Load
• Load
• Load effect
• Load effect
Accessible after opening the instrument;
Accessible after opening the instrument;
Cable inlet by 4 PG screws
Cable inlet by 4 PG screws
Connector cross section 0.5 to 2.5 mm²
Connector cross section 0.5 to 2.5 mm²
• Power supply
• Power supply
• Relay 1/2
• Relay 1/2
• SENS Check
• SENS Check
• Recorder connections each 2-contact
• Recorder connections each 2-contact
• Sensor
• Sensor
• Coarse protection 90 V / 1.5 KA (8/20µs)
• Coarse protection 90 V / 1.5 KA (8/20µs)
• Fine protection 600 Watt
• Fine protection 600 Watt
Safety class
Safety class
2 according to IEC 1010
2 according to IEC 1010
IP 54
IP 54
Functions, limit controller
Functions, limit controller
0.1%
0.1%
max. 600 Ohm
max. 600 Ohm
< 0.1 %
< 0.1 %
2-contact
2-contact
each 2-contact
each 2-contact
2-contact
2-contact
6-contact
6-contact