Selecting the REC 1 recorder output

Selecting the REC 1 recorder output
The display shows:
The display shows:
If the recorder range is exceeded (OFL), the recorder
If the recorder range is exceeded (OFL), the recorder
outputs issue a constant signal of 20.5 mA.
outputs issue a constant signal of 20.5 mA.
An automatic return to the preset recorder range is performed after
An automatic return to the preset recorder range is performed after
eliminating the exceeding of the recorder range.
eliminating the exceeding of the recorder range.
Admissible recorder ranges depending on the measuring range:
Admissible recorder ranges depending on the measuring range:
Measuring range
Measuring range
0 ... 1.999 µS/cm
0 ... 1.999 µS/cm
0 ... 19.99 µS/cm
0 ... 19.99 µS/cm
0 ... 199.9 µS/cm
0 ... 199.9 µS/cm
0 ... 1999 µS/cm
0 ... 1999 µS/cm
0 ... 19.99 mS/cm
0 ... 19.99 mS/cm
0 ... 199.9 mS/cm
0 ... 199.9 mS/cm
0 ... 1000 mS/cm
0 ... 1000 mS/cm
Salinity
Salinity
0.0 ... 70.0
0.0 ... 70.0
When selecting the automatic measuring range, the REC range is always set to the
When selecting the automatic measuring range, the REC range is always set to the
highest measuring range for the selected sensor type (see table on page 30).
highest measuring range for the selected sensor type (see table on page 30).
106
106
REC
REC
min.
min.
range
range
MBA
MBA
fast
fast
0 µS/cm
0 µS/cm
variable 0 µS/cm
variable 0 µS/cm
variable 0 µS/cm
variable 0 µS/cm
variable 0 µS/cm
variable 0 µS/cm
variable 0 mS/cm
variable 0 mS/cm
variable 0 mS/cm
variable 0 mS/cm
variable 0 mS/cm
variable 0 mS/cm
variable 0.0
variable 0.0
Configuration
Configuration
min. range
min. range
∆ of 2 µS/cm,
∆ of 2 µS/cm,
can be freely shifted in
can be freely shifted in
the measuring range
the measuring range
∆ of 20 µS/cm,
∆ of 20 µS/cm,
can be freely shifted in
can be freely shifted in
the measuring range
the measuring range
∆ of 500 µS/cm,
∆ of 500 µS/cm,
can be freely shifted in
can be freely shifted in
the measuring range
the measuring range
∆ of 5 mS/cm,
∆ of 5 mS/cm,
can be freely shifted in
can be freely shifted in
the measuring range
the measuring range
∆ of 50 mS/cm,
∆ of 50 mS/cm,
can be freely shifted in
can be freely shifted in
the measuring range
the measuring range
∆ of 200 mS/cm,
∆ of 200 mS/cm,
can be freely shifted in
can be freely shifted in
the measuring range
the measuring range
∆ of 10,
∆ of 10,
can be freely shifted in
can be freely shifted in
the measuring range
the measuring range
max. MBE
max. MBE
D/span
D/span
(setting
(setting
steps)
steps)
1.999 µS/cm
1.999 µS/cm
19.99 µS/cm
19.99 µS/cm
1 µS/cm
1 µS/cm
199.9 µS/cm
199.9 µS/cm
10 µS/cm
10 µS/cm
1999 µS/cm
1999 µS/cm
100 µS/cm
100 µS/cm
19.99 mS/cm
19.99 mS/cm
1 mS/cm
1 mS/cm
199.9 mS/cm
199.9 mS/cm
10 mS/cm
10 mS/cm
1000 mS/cm
1000 mS/cm
50 mS/cm
50 mS/cm
70
70
5
5