Function 16 (Door contact/boot input)
This allows you to determine how the door contact switch and the boot
contact switch are connected.
The system is factory-set to a closed switch when a door is open/boot is open
(voltage 0 volts). Should the switch used be open when the bonnet is open/
boot is open (voltage 12 volts), function 16 must be programmed to "Switch
opened when door is open".
NOTE
I
The boot contact switch only has to be connected if the lighting for
the passenger compartment (interior light) remains dark when the
boot is opened.
Function 18 (Car Finder/convenience function on)
This function allows you to determine whether the "COMFORT" button
switches additional convenience functions (e. g. Coming Home function) or
whether it should function as a Car Finder. In the second case, the indicators
are activated for 10 min. By pressing the "COMFORT" button again, the
indicator will go out, the alarm system remains activated.
If this function is programmed to "Car Finder", function 8 (Convenience
function) cannot be used.
Function 19 (Switch time for convenience locking function)
In order to be able to use the convenience function, function 4 must be
programmed to "On". In this case, the locking process remains activated for
as long as the "Lock" button is held down. On vehicles equipped with a
factory-set convenience locking module, the e. g. windows or the sliding
sunroof can then be closed. Alternatively, the locking process can be
programmed to a fixed duration of 25 sec.
Function 20 (Deactivation of faulty door contacts)
On vehicles without an interior light delay, this function must remain
programmed to "Off" (factory setting).
On vehicles with interior light delay, this function can be programmed to "On"
so that it detects doors left open by accident. As a result, the door can still be
closed for the first 15 sec. after activation of the alarm system to keep it in the
alarm circuit. If the door is closed after the 15 sec., it will no longer be moni-
tored.