Herunterladen Inhalt Inhalt Diese Seite drucken

Performing A Functional Test - Waeco MagicSafe MS660 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Performing a functional test

7.6
Connecting the gas detector MSG150 (accessory)
(fig. k, page 11)
➤ Disconnect the 12-volt plug from the gas detector cable.
➤ Remove around 10 cm of the outer insulation on the end of the cable.
➤ Connect the black cable to earth (terminal 31).
➤ Connect the yellow and the orange cable of the gas detector to the white
cable from MS660.
➤ Connect the red cable to a cable to a permanent +12 volt charge
(terminal +30). The cable must be fused with at least a 1 A fuse.
If the gas detector is also to be switched to the alarm system as the main
alarm, connect both the relay contacts as follows:
➤ Connect the relay contact 1 (1) to earth (terminal 31).
➤ Connect the relay contact 2 (2) to the grey/white cable of MS660.
8
Performing a functional test
8.1
Testing the hand-held transmitter
➤ Test all of the switching functions with both hand-held transmitters.
If the system does not respond to a hand-held transmitter, program the hand-
held transmitter concerned (see chapter "Learning the hand-held transmitter,
electronic key and radio sensors/reading the PIN code" on page 91).
NOTE
I
The range of the hand-held transmitter can be restricted by solid
metal parts and strong electrical fields. It is usually between 10 m
and 20 m.
78
MagicSafe MS660

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis