Herunterladen Inhalt Inhalt Diese Seite drucken

Waeco MagicSafe MS660 Bedienungsanleitung Seite 80

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Performing a functional test
➤ Move an object into the vehicle interior from outside:
– If an alarm is triggered before you move the object into the vehicle,
reduce the sensitivity.
– If no alarm is triggered, increase the sensitivity.
NOTE for convertibles and vehicles with folding tops
I
For vehicles with cloth or plastic roofs, the sensitivity of the
ultrasonic sensors must be reduced significantly or be disabled
altogether.
➤ Knock on the closed cover to check whether MagicSafe triggers the alarm
when the cover moves.
8.4
Testing other alarm inputs
➤ Test the function of the other alarm inputs in order by triggering an alarm.
➤ Count the number of flashes on the status LED afterwards.
If the number of flashes does not correspond to the specified value, you
need to check the connections and cables.
Number of flashes
0 (status LED off)
1
2
3
4
5
7
8
9
8.5
Testing optical and acoustic signals
➤ Trigger an alarm.
During the alarm, all indicators must be switched on and the vehicle horn or
alarm siren, as well as the status LED, must signal the alarm.
80
Alarm cause
No alarm triggered
Voltage drop sensor
Ultrasonic sensors (interior)
Door/boot contact switch
Bonnet contact switch
Ignition
Additional alarm input
Radio sensor
The battery in the hand-held transmitter is too weak
MagicSafe MS660

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis