Herunterladen Inhalt Inhalt Diese Seite drucken

Structure Components - IFM Electronic Ecomat 100 Handbuch

Vorschau ausblenden Andere Handbücher für Ecomat 100:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

■ Data structure:
CR2101 ConfigStruct
■ Purpose:
Parameter and configuration data
can be written or read.
The data structure is assigned to the
function input "CFG_DATA" via the
ADR operator.

■ Structure components

Name
Data type
GUARDTIME
TIME
LIFETIME
BYTE
Resolution
WORD
Longitudinal axis (X)
SlopeLong
BOOL
Sign
SlopeLong
BOOL
SetZero
SlopeLong
INT
Offset
SlopeLong
BOOL
OffsetWrite
Enable
Transverse axis (Y)
Description
Guarding time of the inclination sensor (ms)
Guarding time of the inclination sensor (ms)
Measured value resolution of the two axes
1 = 0.001° (signed int)
10 =
0.01° (signed int)
100 =
0.1° (signed int)
1000 =
1.0° (signed int)
To change the resolution the sensor is first set to the state
"preoperational" and then back to the state "operational".
At the same time the input "CFG_WRITE" must be set to TRUE.
Sign of the inclination of the longitudinal axis (X)
FALSE (0) = as specified by the manufacturer on the housing
imprint
TRUE (1) = inverted
Sets the application zero point of the longitudinal axis (X),
i.e. the current inclination of the longitudinal axis is processed as
application offset.
To do so, this variable and the input "CFG_WRITE" must be set to
TRUE until the value of the output "CFG_RESULT" is again "1".
Includes the current application offset of the longitudinal axis (X).
The application offset can be set or read.
To do so, the input "CFG_WRITE" or CFG_READ" is set to TRUE.
After a power failure the value is not lost.
SlopeLongOffset is set again to "0" with the variable TRUE.
At the same time the input "CFG_WRITE" must be set to TRUE
until the value of the output "CFG_RESULT" is again "1".
see the following page
INCLINATION SENSOR
TYPE CR2101 ConfigStruct
STRUCT
GUARDTIME: TIME;
LIFETIME: BYTE;
Resolution: WORD;
SlopeLongSign: BOOL;
SlopeLongSetZero: BOOL;
SlopeLongOffset: INT;
SlopeLongOffsetWriteEnable: BOOL
SlopeCrossSign: BOOL;
SlopeCrossSetZero: BOOL;
SlopeCrossOffset: INT;
SlopeCrossOffsetWriteEnable: BOOL
END_STRUCT
END_TYPE
CR2101
37
PAGE

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Cr2101

Inhaltsverzeichnis