Timers:
The tab 'Timers' allows you to add specific events to your Stand-Alone Show.
First, please select one PLEXUS Configuration you wish to edit.
Creates a new Timer.
Removes a Timer. Select the particular Timer first.
Duplicates a Timer. Select the particular list entry first.
In addition, please edit the following columns according to your requirements.
(Perform a double-click to change their values. Use Enter to apply your changes. Use Escape to
cancel.)
'Action'
defines the type of Timer. Applicable values are: 'Scene', 'Intensity', 'Speed,
'Next, 'Previous', 'Stop', 'Play', 'Pause', 'Port 1', 'Port 2', 'Port 3', 'Port 4',
'Port 5', 'Port 6', 'Port 7', 'Port 8', 'Port 9', 'Port 10'. 'Scene' will trigger a specific
Scene to be played. 'Intensity' will trigger the brightness of the output to change.
'Speed' will trigger a change of tempo. 'Next' or 'Previous' skip to the last or next
entry. 'Stop', 'Play', and 'Pause' end, start, or halt the playback. 'Port' will trigger
the specific Port of the extension port.
'Value'
is a field that depends on the 'Action'. Enter a number to specify a certain 'Scene'.
Enter a value from 0 to 100 for 'Intensity'. Enter a value from 1 to 1000 for 'Speed'.
Select 0 (Off) or 1 (On) for 'Port'.