  • DEUTSCH, seite 1
Open up the pressure/ quantity regula-
tor on the hand spray gun completely,
direction + until stop.
Set the operating pressure on the appli-
ance to the minimum value.
Set temperature regulator to min. 100
°C.
Danger
Scalding danger!
We recommend the following cleaning tem-
peratures:
– De-preserve, contaminations contain-
ing strong fat contents
100 -110 °C
– De-frosting of surcharge substances,
partially facade cleaning
up to 140 °C

After each operation

Danger
Danger of scalding by hot water. After the
operation with hot water or steam, the de-
vice must be operated with openend gun
with cold water for at least two minutes.
After operation with detergent
Set dosing value for detergent to "0".
Set the appliance switch to "I".
Open the hand spray gun and rinse the
appliance for at least 1 minute.
Turn off the appliance.
Set the appliance switch to "0".
Shut off water supply.
Turn on pump shortly (appr. 5 seconds)
with device switch.
Pull main plug out of socket with dry
hands only.
Remove water connection.
Activate hand spray gun until device is
pressure less.
Secure hand spray gun, Figure 8 (A).
28
English
Lock in the steel pipe into the holder of
the appliance hood.
Roll up high pressure hose and electri-
cal conduit and hang them into the re-
spective holders.
Device with hose drum:
Before rolling up, stretch out the high
pressure hose.
Turn the hand crank clockwise (Direc-
tion of the arrow).
Note
Do not twist high pressure hose and electri-
cal conduit.
Warning
Frost will destroy the not completely water
drained device.
Store in a frost free area.
If the device is connected to a chimney, the
following must be observed:
Warning
Threat of damage by penetrating cold air
through the chimney.
Disconnect device from chimney when
outside temperature drops below 0 °C.
If it is not possible to store frost free, shut
down device.

Shutdown

For longer work breaks or if a frost free stor-
age is not possible:
Drain water.
Flush device with anti-freeze agent.
Empty detergent tank.
Dump water
Screw off water supply hose and high
pressure hose.
Screw off supply hose at boiler bottom
and drain heating spiral empty.
Operate device for max. 1 minute until
the pump and conduits are empty.

Quicklinks ausblenden: