Note
To prevent damage due to too much pres-
sure, always position high pressure ray first
from a greater distance towards object to
be cleaned.
Working with the high pressure nozzle
The spray angle is essential for the effec-
tiveness of the high pressure ray. Normally
work is performed with a 25° flat ray nozzle
(included).
Recommended nozzles are deliverable as
accessories
– For strong contaminations
0° full ray - nozzle
– For sensitive surfaces and light contam-
inations
40° flat ray - nozzle
– For thick layered, persistent contamina-
tions
Dirt grinder
– Nozzle with adjustable spray angle, for
adaption to different cleaning tasks
Angle-Vario-Nozzle
Recommended cleaning method
– Loosen the dirt:
Spray detergent economically and let it
work for 1...5 minutes but do not let it
dry up.
– Remove the dirt:
Spray off loosened dirt with the high-
pressure ray.
Operating with cold water
Removal of light contaminations and clear
rinse, i.e.: Gardening tools, terrace, tools,
etc.
Set operating pressure according to
need.
Set temperature regulator to "0".
Operating with hot water
Danger
Scalding danger!
Set temperature regulator to desired
temperature.
We recommend the following cleaning tem-
peratures:
– Light contaminations
30 -50 °C
– Contaminations containing protein, i.e.
in the food processing industry
max. 60 °C
– Vehicle cleaning, machine cleaning
60 -90 °C
Safety switch-off
If the hand-spray gun is not closed or
opened for more than 30 minutes, the pump
is automatically switched off for safety rea-
sons.
Press the appliance switch for restart to
"0" and then to "I".
Note
You can also get an EPROM without
switch-off (Order No. 6.682-595) from Cus-
tomer Service.
Operating with steam
Danger
Scalding danger! When operating with tem-
peratures above 98 °C, the operating pres-
sure must not exceed 3.2 MPa (HDS 1295:
2.8 MPa) .
Therefore the following measures must def-
initely be performed:
Replace the high pressure nozzle
with the steam nozzle.
Order No.
Type
4.766-023
HDS 995
4.766-024
HDS 1295