Herunterladen Inhalt Inhalt Diese Seite drucken

Lock The Machine In Position; Connecting To Power Supply; Vacuum Mode - Stihl SE 122 Gebrauchsanleitung

Vorschau ausblenden Andere Handbücher für SE 122:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
Lock the machine in
position
Apply the brake on the caster to lock the
machine in a particular position.
SE 122, SE 122 E
Connecting to Power
Supply
The mains voltage must match the
operating voltage specified on the rating
plate.
The machine must be connected to the
power supply via an earth-leakage
circuit breaker to disconnect the power
supply if the leakage current to earth
exceeds 30 mA for 30 ms.
The power connection must correspond
to IEC 60364 and relevant national
regulations.
Note the minimum conductor cross-
sections when working with extension
leads. Extension leads must be routed
so that the protection class of the
machine is maintained.
Cable length
Cross-section
220 V – 240 V:
up to 20 m
1.5 mm
20 m to 50 m
2.5 mm
100 V – 110 V:
up to 10 m
2.0 mm
10 m to 30 m
3.5 mm
N
Ensure that the vacuum cleaner is
switched off.
N
Plug the power cord into a properly
installed outlet.

Vacuum mode

SE 122
Switch positions
Switch position 0 – Vacuum cleaner is
switched off
Switch position I – Vacuum cleaner is
switched on
SE 122 E
2
2
2
2
Power tools (max. 2400 W) are plugged
into the machine socket (1).
English
0
auto
I
1
2
21

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis