Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 312
• Follow the manufacturer's sharpening and
maintenance instructions for the saw chain. De-
creasing the depth gauge height can lead to in-
creased kickback.
• Do not saw with the tip of the guide bar. There is a
risk of kick-back.
• Make sure that there are no nails or metal pieces in
the cutting area.
• Also be careful when sawing hardwoods where the
saw chain can get caught. This can cause kick-
back.
• Start cutting at full power and always keep the
chainsaw at maximum speed while sawing.
• Make sure that there are no objects on the floor
that you can trip over.
Residual risks
The product has been built according to state-of-
the-art and the recognised technical safety rules.
However, individual residual risks can arise during
operation.
• Damage to hearing if the stipulated hearing protec-
tion is not worn.
• Residual risks can be minimised if the "Safety In-
structions" and the "Intended Use" together with
the operating manual as a whole are observed.
• Use the product in the way that is recommended in
this operating manual. This is how to ensure that
your product provides optimum performance.
• Furthermore, despite all precautions having been
met, some non-obvious residual risks may still re-
main.
DANGER
DANGER OF INJURY!
Contact with the saw chain can lead to fatal cuts.
Never touch the saw chain with your hands while it is
running.
DANGER
RISK OF KICK-BACK!
Kick-back can lead to fatal cuts.
WARNING
DANGER OF BURNING!
The chain and guide rail heat up during operation.
10
|
GB / CY
WARNING
This power tool generates an electromagnetic field
during operation. This field can impair active or pas-
sive medical implants under certain circumstances.
In order to prevent the risk of serious or deadly inju-
ries, we recommend that persons with medical im-
plants consult with their physician and the manufac-
turer of the medical implant prior to operating the
power tool.
WARNING
In case of extended working periods, the operating
personnel may suffer circulatory disturbances in their
hands (vibration white finger) due to vibrations.
Raynaud's syndrome is a vascular disease that caus-
es the small blood vessels on the fingers and toes to
cramp in spasms. The affected areas are no longer
supplied with sufficient blood and therefore appear
extremely pale. The frequent use of vibrating prod-
ucts can cause nerve damage in people whose cir-
culation is impaired (e.g. smokers, diabetics).
If you notice unusual adverse effects, stop working
immediately and seek medical advice.
9

Technical data

Type of engine
Displacement
Idle speed n
0
Speed n
max
Engine output
Fuel
Tank contents
Oil tank capacity
Spark plug
Chain speed
Guide rail
Cutting length*
Chain pitch
Number of chain wheel teeth
Type of saw chain
Type of guide rail
Driving link thickness
2-Stroke engine/
air cooled
53 cm³
3100 ± 300 rpm
11500 rpm
2.0 kW
Regular grade petrol/
lead-free max.
10% bioethanol
0.55 l
0.26 l
L8RTC
22.1 m/s
18"
44 cm
8.255 mm
(0.325")
7 teeth
KANGXIN
.325.058-72
KANGXIN
BE18-72-5810P
1.47 mm (0,058")
Inhaltsverzeichnis
loading

Inhaltsverzeichnis