Herunterladen Inhalt Inhalt Diese Seite drucken

For Pumps With A Float - Ibo Rainer 1200 Auto Bedienungsanleitung

Tauchpumpen
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

For pumps with a float

Problem
Possible cause
The pump is not
The float switch is in the
working
"off".
There is not enough water in the pump
sump to lift the float to the 'on' position.
The float has become caught on
something and cannot move to the 'on'
position.
No mains power supply.
The pump is blocked.
The pump does
The float is caught on the side of the tank
not start
or on the discharge pipe (hose).
The float is stuck in the 'on' position.
The pump
The pump is not fully submerged in
operation is
water.
intermittent
The thermal
The temperature of the pumped water
switch fitted
is too high.
inside the pump
is cutting off the
power supply
The pump
No non-return valve fitted on the
frequently
discharge connection. When the
switches on
pump
pumps the water down to the level at
and switches off
which the float switch switches the
pump off, water from the discharge
pipe (hose) flows back into the sump.
Once enough water has flowed in, the
float switch switches the pump on.
The cycle repeats continuously.
Troubleshooting
19
Installatio
n
Solution
Wait until there is enough water in the
pump sump to automatically switch the
pump on via the float.
Check that the float can move freely
Check that the pump's plug is properly
inserted into the socket
Check the circuit breakers in the building and
any installation fuses that may have cut off the
mains supply
Check that there is a power supply in the
vicinity of the building; the power may have
been cut off by the electricity supplier across a
wider area
Disconnect the pump from the mains supply.
Once you have removed the pump from the
tank, release the pump impeller. Before
reinserting the pump into the tank, check that
the impeller rotates freely.
Check whether the float is caught on
the tank wall, preventing automatic
switch-off.
Unblock the float.
Replace the float at an authorised service centre.
Check the water level in the pump sump.
Unblock the stuck float.
Check that the water temperature is not too
high for this type of pump.
Fit a non-return valve on the pump's
discharge connection to prevent water from
flowing back into the pump sump.
Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Rainer 1200 auto stormRainer 1200 inoxRainer 1000 inox003448Kat01501Kat01500 ... Alle anzeigen

Inhaltsverzeichnis