14. Start up
1. Ensure that the filter is clean and that the pool and system is free from copper, iron and algae, and that any heating
equipment installed is compatible with the presence of salt in the water.
2. Balance the pool water. This will allow you to achieve a more efficient treatment with lower free chlorine concentrations
in the water, as well as a longer operation of the electrodes together with a lower formation of calcareous deposits in the
pool. a) The pH should be 7.2-7.6 b) The total alkalinity should be 60-120 ppm.
3. Although the system can operate in a salinity range of 5-12 g/L, the recommended optimum salt level of 5 g/L should
be maintained, adding 5 kg for every m³ of water if it did not previously contain salt. Always use common salt (sodium
chloride), without additives such as iodides or anti-caking agents, that is suitable for human consumption. Never add salt
through the cell. Add it directly to the pool or in the balance tank (away from the pool drain).
4. Chlorine treatment should be carried out when salt is added, and if the pool is to be used immediately. As an initial dose,
2 mg/L trichloroisocyanuric acid may be added.
5. Before starting the work cycle, disconnect the control unit and run the purifier pump for 24 hours to ensure the salt is
completely dissolved.
6. Next, turn on the salt electrolysis system, setting the salt electrolysis output level so that the free chlorine level is maintained
within the recommended levels (0.5-1.5 ppm). NOTE: a test kit must be used to determine the free chlorine level.
7. In pools exposed to strong sunlight or intensive use, it is advisable to maintain a level of 25-30 mg/L of stabiliser
(isocyanuric acid). Under no circumstances should a level of 75 mg/L be exceeded. This will help to prevent the
destruction of free chlorine in the water by sunlight.
EN
15. Inside view of the control box
Note: pH KIT and ORP KIT only available for the scalable models.
Switch
Power supply
Cell
ON/OFF
230 V ac
Fuse
pH
ORP
sensor
sensor
pH pump fuse
pH
ORP
pH
pump
Flow
ORP
Cover
Cover
Flow
detector
External
ORP
control
137