12. Installation of the PH / ORP probe (

1. Insert the pH/ORP probe supplied with the device into the corresponding housing of the probe holder (A).
2. To do this, loosen the fitting nut and insert the sensor into the holder.
3. The sensor must be inserted into the fitting in such a way as to ensure that the sensor at the end is always submerged in
the water flowing through the pipe.
4. Always install the pH/ORP probe either in a vertical position or at a maximum inclination of 40° (B).

13. Removal of front cover and connection cover

1. Remove screws under the outer frame (A).
2. Remove outer frame (A)
3. Unscrew the fixing screws (B) on the front of the unit.
4. Pull the cover (B) out to give access to fuse pump and connections.
(A)
pH KIT and ORP KIT only available for scalable models