Replace the steel cable
Replace damaged or worn cables
Remove the cable from the drum
1. Remove the excess cable from the drum through the bracket.
2. Loosen the screws that secure the end of the cable to the cable drum
wall.
3. Remove the end of the cable and discard the waste cable.
Installing new cables
1. To make the cable installation easier, completely unwrap the new cable
coil and carefully remove the cable packaging. The cable has elastic
The drum has a 30- degree, 4- inch bend at the end to help the cable enter.
Drum.
2. Insert the steel cable into the drum along the curved pipe.
The cable should be wound in a clockwise direction (see Figure 4 ).
Figure 3
(The image is for reference only and may differ from the original
appearance)
3. The end of the steel cable is fixedly connected to the drum with screws .
4. Tighten the fixing screws.
5. Coil the remaining cable into the drum.
Machine storage requirements
Motor-driven electrical equipment and cables should be stored indoors and
protected from rain. The machine should be locked up and stored to
prevent access by untrained personnel or children. This tool can cause