HOMCOM FDP20-2024R5 Bedienungsanleitung Seite 5

Tragbare klimaanlage
Inhaltsverzeichnis
EN
available and in good working order. Hoses shall be complete with leak free disconnect
couplings and in good condition. Before using the recovery machine, check that it is in
satisfactory working order, has been properly maintained and that any associated
electrical components are sealed to prevent ignition in the event of a refrigerant
release. Consult manufacturer if in doubt.
The recovered refrigerant shall be returned to the refrigerant supplier in the correct
recovery cylinder, and the relevant Waste Transfer Note arranged. Do not mix
refrigerants in recovery units and especially not in cylinders.
If compressors or compressor oils are to be removed, ensure that they have been
evacuated to an acceptable level to make certain that flammable refrigerant does not
remain within the lubricant. The evacuation process shall be carried out prior to
returning the compressor to the suppliers. Only electric heating to the compressor body
shall be employed to accelerate this process. When oil is drained from a system, it shall
be carried out safely.
Service shall only be performed as recommended by the equipment manufacturer.
Maintenance and repair operations requiring the assistance of other skilled personnel
shall be carried out under the supervision of the person competent in the use of
flammable refrigerants.
Any person who is involved with working on or breaking into a refrigerant circuit should
hold a current valid certificate from an industry-accredited assessment authority, which
authorises their competence to handle refrigerants safely in accordance with an
industry recognised assessment specification.
Please note this product has non serviceable parts. The coolant gas in this appliance
cannot be replaced/regased.
Do not place the unit in front of curtains or drapes in case they fall against the back air
intake.
lf using this appliance with an extension lead do not exceed the maximum rated
wattage of the extension lead.
Do not use this appliance in bathrooms or wet room environments/locations.
Appliance must not be used in closed cupboards or changing rooms.
Do not cover the appliance with clothing or any other fabric.
Appliance must be kept at a suitable distance from walls, furniture and curtains to
prevent them from overheating due to poor ventilation.
Appliance should not be used when no one is at home. lf you are away for long periods
of time, turn off the power and remove the plug from the socket.
The filter should be cleaned or replaced periodically to prevent insufficient air flow
caused by a buildup of dust particles. Poor air flow will cause overheating, reduce the
performance of the unit and add more risk.
This appliance is designed for INDOOR DOMESTIC USE ONLY.
The appliance shall not be installed in a laundry room.
4
Inhaltsverzeichnis
loading