Instructions for the Installer

Installation and connection must be
carried out in compliance with the
regulations in force. Any interventions
must be carried out when the
appliance is switched off. Only
accredited engineers may work on the
appliance.
The manufacturer disclaims any
liability if the safety measures are not
observed.
Connecting to the electrical supply
Before connecting to the electrical supply, please
make sure:
- The fuse and the domestic electrical
installation must be designed for the
max. load of the appliance (see rating
plate).
- The domestic electrical installation must
be equipped with a proper earth
connection in accordance with the
regulations in force.
- The socket or the multi-pole off switch
must be easy to access after the
appliance has been installed.
This appliance is supplied with a connection
cable incorporating a standard plug, suitable for
the total electric load shown on the rating plate.
The plug is to be inserted into a suitable wall socket.
If you require a direct connection to the electric
network (mains), it will be necessary to fit between
the appliance and the mains an omnipole switch,
with a minimum gap between contacts of 3 mm,
suitable for the required load and in compliance
with rules in force. The green & yellow ground
wire must not be interrupted by the switch and it
should be 2-3 cm. longer than the other cables.
The mains cable and plug as supplied are to
be connected to a shockproof socket (230 V~, 50
Hz). The shockproof socket must be installed in
accordance with the regulations.
34
The following types of mains cable are suitable,
taking the necessary rated cross section into
account: H07 RN-F, H05 RN-F, H05 RR-F, H05
VV-F, H05 V2V2-F (T90), H05 BB-F.
The connection cable must in any case be laid
out so that at no point does it reach 50°C (over
room temperature).
After the connection has been carried out, the
heating elements must be tested by being operated
for about 3 minutes.

Terminal block

The oven is fitted with an easily accessible terminal
block which is designed to operate with a single-
phase power supply of 230 V (Fig. 38).
Letter L -
Live terminal
Letter N -
Neutral terminal
or E -
Earth terminal
Fig. 38