Alarm text
Cause
Target pressure
The system pressure cannot be refi lled to reach the
cannot be reached
desired set value.
Supply voltage
The supply voltage has been interrupted.
interrupted
15.1. Disassembly
Any inoperable All-in-One+ Connect must be disassembled and disposed of in an environmentally friendly manner.
•
Remove the mains adapter and, if necessary, the battery.
•
Disassemble the devices, including the connection fl ange.
15.2. Disposal
Unless a take-back or disposal agreement has been made, recycle the disassembled components:
•
Scrap metals
•
Return synthetic elements for recycling
Max. operating pressure
Max. operating temperature
Outlet pressure
Medium
Filling capacity
Voltage power supply
Battery
Mounting position
Remedy
The target pressure must be at least 1.5 bar lower
than the inlet pressure. Please check whether the
target pressure setting is too high. You may also in-
crease the system pressure by adjusting the pressure
reducing valve to reach the target pressure or con-
tact the SYR service.
Please ensure that the mains voltage is switched on
and the device is connected to the mains adapter.
Unit
bar
10 bar
°C
30 °C (inlet); 65 °C (outlet)
bar
1 - 5 bar (factory setting 3 bar)
Drinking water
m
/h
0,5 (0,3 when using the 2.5 l cartridge)
3
V DC
12
V
9 (block)
Main axis horizontal
15. Disassembly and disposal
16. Technical specifi cations
37