6.1. Safety instructions for assembly
The assembly and commissioning of the SYR All-in-One+ Connect may only be carried out by authorized, qualifi ed and instructed personnel
who have the corresponding special knowledge.
The general safety instructions for drinking water installations have to be met, amongst others:
•
Drinking water supply systems TRWI - DIN 1988, DIN EN 806, DIN EN 1717
•
Instructions and regulations of the local water supply
Attention!
Potential material damage in case of improper drinking water installation!
•
Mount the All-in-One+ Connect in accordance with the instructions for use.
Check connections for leaks.
•
Avoid water hammers, e.g. from solenoid valves downstream in the system.
Attention!
Dirt in the drinking water supply line can lead to malfunctions in the device.
•
We recommend the installation of a fi lter (e.g. DRUFI+ DFR) to protect the installation downstream!
Attention!
Potential material damage in case of improper electrical installation!
•
Use only the supplied mains adapter to connect the device to the mains.
6.2. Assembly
The All-in-One+ Connect is mounted where the heating installation is fi lled for easy access.
•
Turn off the water supply before starting the assembly work.
•
The installation must be carried out free of stress.
Before installation, the pipes must be fl ushed.
A drinking water fi lter according to DIN 1988 (e.g. SYR DRUFI+) should be installed upstream of the All-in-One+ Connect to protect the valve
from contamination.
6.2.1. Assembly bracket
Set a dedicated position for your SYR All-in-One+ Connect. Use the enclosed holder to stabilise the system.
•
Mark two drilled holes at a distance of 126 mm
on the wall [image 1].
•
Drill two holes at the marked points (8mm drill bit).
Screw the holder to the wall using the additional material
supplied (2 x dowels, 2 x cylinder head screws 6.3 x 50;
2 x washers A 6.4) [image 2].
6. Assembly
[image 1]
[image 2]